{"product_id":"pl3-mpd-cw51-82-100ab-yt0yt-lz-2-d03-12-n10-m1","title":"100A Portable Distribution Panel - 480V-208Y\/120 3PH - (2) DR100 \u0026 (12) 5-20R GFCI - DR100 Inlet","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eMPD-CW51-82.100AB-YT0YT-LZ-2.D03-12.N10-M1 -Temporary Power Distribution System\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eLine-in Cord: N\/A\u003c\/td\u003e\n\u003ctd\u003eMax Primary OCP: 100A @ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-in Cord Cap: DR100 UL1682 100A Male Pin \u0026amp; Sleeve Inlet [208\/125V]\u003c\/td\u003e\n\u003ctd\u003eMax Secondary Output: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003ePrimary Voltage (V): 208\/120V AC Wye\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eNEMA 3R Indoor or Outdoor Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Phase (PH): 3-Phase (3PH)\u003c\/td\u003e\n\u003ctd\u003eMade in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Frequency (HZ): 60 Hz (60-cycles)\u003c\/td\u003e\n\u003ctd\u003eNRTL Certified to UL 1640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Panel: 208Y\/120V 3PH 100A MCB N3R\u003c\/td\u003e\n\u003ctd\u003eNRTL Certified to CSA C22.2 No. 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Breaker: (2) 50A 3P MCB [250V]; (12) 20A 1P MCB [125V]\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Outlets: (2) DR100 UL1682 100A 3P+N+G Pin \u0026amp; Sleeve Receptacle [208\/125V]; (12) 5-20R NEMA GFCI DPLX [125V]\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Protection: MCCB Circuit Breakers; MCB Circuit Breakers; GFCI's\u003c\/td\u003e\n\u003ctd\u003ePowder Coat Finish Standards:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransformer (KVA): -\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-523\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage (V): -\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-3359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Phase (PH): -\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Frequency (HZ): -\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-3363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Panel: -\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-2794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Breakers: -\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Outlets: -\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Protection: -\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor: Blue Powder Coated Steel Skid Mounting Plate\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoors: (2) \u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Material: Steel\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eFrame Finish: High-strength TGIC Polyester Powder Coated Blue\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCart Handle Orientation: Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifting Eyelet: (4) Top Located\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkid Pockets: (2) Bottom Located\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasters:Ã‚Â -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 55.5\"-L x 33.5\"-W x 70\"-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 1650 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram.\u003c\/td\u003e\n\u003ctd\u003e*All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250*\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nMade in Texas\nThe Larson Electronics MPD-CW51-82.100AB-YT0YT-LZ-2.D03-12.N10-M1Ã‚Â Power Distribution Substation provides operators the ability to safely tap into and distribute 208\/120V AC power from a variety of sources including generators and direct grid power.\n*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*\nThe MPD-CW51-82.100AB-YT0YT-LZ-2.D03-12.N10-M1Ã‚Â temporary power distribution system gives operators the ability to power their 120 volt equipment from a single system. \nOperation: \nÃ¢â‚¬Â¢\tPrimary Voltage: 3-phase 208\/120V AC Wye\nÃ¢â‚¬Â¢\tPrimary Receptacles: (2) DR100 UL1682 100A 3P+N+G Pin \u0026amp; Sleeve Receptacle [208\/125V]; (12) 5-20R NEMA GFCI DPLX [125V]\nÃ¢â‚¬Â¢\tTransformer: N\/A\nÃ¢â‚¬Â¢\tSecondary Voltage: N\/A\nÃ¢â‚¬Â¢\tSecondary Receptacles: N\/A \n*See specification table at the top of the page for more information about the power distribution system. \nProtective Construction: This temporary power distribution unit is fully enclosed and is ruggedly constructed to withstand demanding conditions and industrial applications.  The system is accessible via two doors at each end for access to breakers on the panels and a center-located door for access to receptacles. The model is equipped with bottom-located forklift skid pockets and four top-located lifting eyelets, which allows easy lifting with cable or chain hooks.\nThe power distribution system is constructed of steel with a polyester powder coated blue finish for durability against dirt, moisture and mild corrosion. This special coating creates a high-strength barrier for protection from accidental bumps and scratches. The TGIC polyester powder coat finish offers reliable resistance against chemicals, UV light (sun light) and degrading elements in outdoor locations. Our powder coating solution ensures robust color retention for many years without fading. Custom colors, such as black, grey, desert tan or forest green, and galvanized finishes are available upon request. Non-standard powder coat colors or galvanized finishes may increase price and lead times. \nThe transformer and load center\/distribution assembly is mounted to a standard steel cube style frame resulting in an extremely stable, durable and mobile power distribution platform. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Larger units are available upon request and can be equipped with skids or trailer mounted.\nCertification: All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request.\nGrounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. \n~Please check all motor loads for dual rated motors that will work 208 or 240.~\n Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments.\nCustom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or  to discuss your specific requirements.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40774985777333,"sku":"PL3-MPD-CW51-82.100AB-YT0YT-LZ-2.D03-12.N10-M1","price":30690.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-MPD-CW51-82.100AB-YT0YT-LZ-2.D03-12.N10-M1.jpg?v=1628916821","url":"https:\/\/getcahits.com\/zh\/products\/pl3-mpd-cw51-82-100ab-yt0yt-lz-2-d03-12-n10-m1","provider":"PuriLite","version":"1.0","type":"link"}