{"product_id":"pl3-ind-hvac-dtw-uvc-r6-ss-12-2l-n3r-120v","title":"12\" UV Air Duct Disinfection 3-Lamp Fixture - UV-C - Destroys Airborne Bacteria \u0026 Viruses - 120V - 7.2W Total UV Output - NEMA 3R Ballast Box","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003eThis unit is Made In USA - Manufactured in Texas\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eIND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120V UV Air Duct Disinfection System\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\/Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eLamp Technology: UV-C Fluorescent\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eNRTL Listed to UL 508A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Housing Dimensions:  16-13\/16\"H x 8-1\/8\"W x 4-7\/16\"D\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eNRTL Listed to CSA C22.2 No. 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth (Inside Duct) for Partial Internal Mount:  15\"\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eT8 Bulb Shape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: -\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eShort-wave Germicidal Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: 120V AC, 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eDestroys Airborne Bacteria and Viruses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWattage: 10W Per Lamp\u003c\/td\u003e\n\u003ctd\u003eNon-Ozone Producing Germicidal UV Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Watts: 20W\u003c\/td\u003e\n\u003ctd\u003eEPA Reg. No 98409-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Output: 3.6W per lamp\u003c\/td\u003e\n\u003ctd\u003eEPA Est. No. 98409-TX-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal UV Output: 7.2W\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R Rated Ballast Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiance (single lamp): 30 uW\/cm2 @ 1 meter\u003c\/td\u003e\n\u003ctd\u003eGasketed Mount Keeps Moisture Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Lifespan: 8,000+ Hours\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Wavelength: 254nm peak\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Base: G13 (Medium Bi-Pin)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Lamp: FRL-12-1X-T8-10W-UV-C \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBeam Angle:  360Ã‚Âº\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Configuration: Flood\u003c\/td\u003e\n\u003ctd\u003eSpecial Orders - Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps: 0.21A @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temp Range:  -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMaterials: 304 Stainless Steel Enclosure \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eIndicator Lights: Operational Light (confirms on) and Replace Lamp (lamp no longer functional) indicator lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMounting: Partial Internal Duct Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: justify;\"\u003e***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device\nin any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.*** \u003c\/td\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 100%;\"\u003e\nThis unit is Made In USA - Manufactured in Texas\nThe IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â from Larson Electronics is a Air Duct Disinfection System that works to disinfect air moving through a duct system via germicidal ultraviolet (UV) rays. This unit helps to control the spread of airborne cold and flue virus as well as other airborne transmitted disease. This anodized aluminum air duct disinfection system features three of 10 watt UV bulbs that each produce 3.6 watts (7.2W total) of UV output at a wavelength of 254nm. The IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â is designed to be mounted inside an air duct and operates on 120V AC current. This unit can be installed on rooftop duct units with a gasket mount, outdoor rated indicator light, and NEMA 3R rated ballast enclosure.\n*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.* \nThe IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with three UVC fluorescent lamps, this system offers 7.2 total watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â can be used continuously in air ducts such as those found in HVAC systems.\nOperation: This UV air duct disinfection system projects ultraviolet rays inside the air duct it is mounted in. The air flowing through the duct that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the duct is constantly being purified as it flows through the UV rays being produced by the fixture.\nConstruction: The enclosure of the IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â is built from 304 stainless steel. In-Operation and Replace-Lamp indicator lamps allows for operators to check the status of the UV bulb(s) without removing the fixture from the air duct or being exposed to harmful UV radiation.\nMounting: The IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â is designed to be mounted inside an air duct. The system is intended to be mounted in a partial internal style with the bulb(s) being mounted inside of the air duct and the electronics mounted on the outside of the duct. \nThe IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120V can be mounted on rooftop ducts and HVAC units. The design of this air duct disinfection system requires the ballast box to be mounted outside of the duct. For rooftop units, the externally mounted ballast box will be exposed to the elements. The IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120V features a NEMA 3R ballast enclosure along with a gasketed mount between the ballast enclosure and mounting surface to keep moisture out. The indicator light is also outdoor rated.\nNote on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.\nApplications: This ultraviolet UV air duct disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120VÃ‚Â is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more. \nLarson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or  to discuss your specific requirements.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40705199964341,"sku":"PL3-IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120V","price":2562.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-IND-HVAC-DTW-UVC-R6-SS-12-2L-N3R-120V.jpg?v=1628352489","url":"https:\/\/getcahits.com\/zh\/products\/pl3-ind-hvac-dtw-uvc-r6-ss-12-2l-n3r-120v","provider":"PuriLite","version":"1.0","type":"link"}