{"product_id":"pl3-ind-ahf-bx-uvc-r1-120v-15c","title":"Larson UV Air Sanitation Purifier - 120V - (2) 15W T8 UVC Lamps - 15' 16\/3 SOOW Cord - Occupied Areas","description":"\u003cstrong\u003ePuriLite suggests you place an order directly with us for large Larson orders due to the potential customization requirements. Please call us at 1(647) 254-9757 to place your order. If you prefer to place your order online, a PuriLite agent will be in touch with you to discuss any custom options.\u003c\/strong\u003e\u003cbr\u003eThis unit is Made In USA - Manufactured in Texas\r\u003cbr\u003eThe IND-AHF-BX-UVC-R1-120V-15C Industrial UV Air Purifier  from Larson Electronics  actively disinfects the surrounding air in occupied areas without noise. This unit uses two T8 UVC lamps that provide 10.6 watts of total UV output during UV treatment. Designed for free-standing operation and permanent installation on walls, surfaces or ceilings, the UV air purifier operates on 120V AC and is protected by 304 stainless steel enclosure. The IND-AHF-BX-UVC-R1-120V-15C is equipped with a MERV 16 rated air filter.\r\u003cbr\u003e*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. \r\r\u003cbr\u003e*\r\u003cbr\u003eThe IND-AHF-BX-UVC-R1-120V-15C is a powerful sanitation solution for occupied areas in buildings. Equipped with two T8 UVC fluorescent lamps, this system offers 10.6 watts of total UV output, within the 200nm - 280nm UV-C range (254 nm peak). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern inside the  unit. The UV chamber has a polished surface to maximize  light distribution during UV treatment. Constructed of 304 stainless steel, the UV lights are enclosed inside the unit preventing UV exposure in occupied areas. A limit safety switch ensures automatic disconnection of power to the system during servicing, installation or maintenance. LED indicator lights on the unit notify individuals when the system is in operation and when the lamps must be replaced (one LED indicator light per lamp).\r\u003cbr\u003eBlower Capacity\r\u003cbr\u003e72 cubic ft\/minute\r\u003cbr\u003eNominal Fixture Capacity\r\u003cbr\u003e54 cubic ft\/minute\r\u003cbr\u003eMax Treatment Capacity\r\u003cbr\u003e3,240 cubic ft\/hour\r\u003cbr\u003eMax Room Size @ 3 Air Changes\/Hour\r\u003cbr\u003e1,080 cubic ft\r\u003cbr\u003eMax Room Size @ 4 Air Changes\/Hour\r\u003cbr\u003e648 cubic ft\r\u003cbr\u003eMax Room Size @ 5 Air Changes\/Hour\r\u003cbr\u003e810 cubic ft\r\u003cbr\u003eMax Room Size @ 6 Air Changes\/Hour\r\u003cbr\u003e540 cubic ft\r\u003cbr\u003eOperation:\r\u003cbr\u003eSurrounding \"dirty\" air is drawn into the UV purifier via washable electrostatic filters. The \"dirty\" air passes through the UV sanitation chamber where it is treated with UVC light using the two T8 fluorescent lamps. The disinfection process kills up to 99.9% of viruses, bacteria, mold, spores, and other harmful microbes. Clean sanitized air exits the chamber through a louvered exhaust panel and is released back into the environment. This low-maintenance air disinfection process is continuous and quiet.\r\u003cbr\u003eMERV Filter:\r\u003cbr\u003eHVAC air filters are rated according to the minimum efficiency reporting value (MERV). The MERV rating measures how effectively the filter prevents dust and other contaminants from getting through and into the circulating air. Larson Electronics utilizes filters that have a rating of MERV 16 in our UV air sanitation purifiers. This level of air filter can stop particulates that range from 0.3 to 1.0 microns in size. MERV 16 filters are generally used in residential, commercial, and hospital settings.\r\u003cbr\u003e5-15 Straight Blade Plug\r\u003cbr\u003eL5-15 Twist Lock Plug\r\u003cbr\u003eFlying Leads \/ Pigtail Wires\r\u003cbr\u003eWiring\/Plug:\r\u003cbr\u003eThis unit is equipped with 15 feet of 16\/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground or NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug.\r\u003cbr\u003eMounting:\r\u003cbr\u003eThe IND-AHF-BX-UVC-R1-120V-15C can be deployed as a free-standing unit in occupied areas. This unit is also compatible with permanent installations on walls, surfaces or ceilings. We offer models with 2x2 and 2x4 troffer mount features for installations on ceilings with tiles or grids.\r\u003cbr\u003eNote on Environment:\r\u003cbr\u003eSunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.\r\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\r\u003cbr\u003eAir sanitation, occupied areas, food processing, pharmaceutical, schools, labs, warehouses, buildings, industrial, manufacturing, office, air disinfection, UV treatment and many more.\r\u003cbr\u003eLarson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your \u003cstrong\u003eSpecifications\u003c\/strong\u003e. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1(647) 254-9757 or\r\u003cbr\u003eContact info@purilite.ca\r\u003cbr\u003eto discuss your specific requirements.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eLamp Technology:  UV-C Fluorescent\u003cbr\u003eLamp Quantity:   (2) UVC Lamps\u003cbr\u003eDimensions:   36\"-L x 7.75\"-W x 11.22\"-H\u003cbr\u003eWeight: Â 65 lbs\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e  120V AC\u003cbr\u003eTotal Watts:  30W\u003cbr\u003eSingle-lamp Watts:  15W\u003cbr\u003eTotal UV Output:  10.6W\u003cbr\u003eSingle-lamp UV Output:  5.3W\u003cbr\u003eTotal UV Irradiance:  88 uW\/cm2 at 3 feet\u003cbr\u003eExpected Lifespan:  8,000+ Hours\u003cbr\u003eUV Wavelength:  254nm\u003cbr\u003eLamp Type:  T8 1.5F\u003cbr\u003eLamp Base:  G13\u003cbr\u003eReplacement Lamp:  -\u003cbr\u003eBeam Angle:  360Âº\u003cbr\u003eLight Configuration:  Flood\u003cbr\u003eInternal Reflector:  Polished\u003cbr\u003eLED Indicator Lights : In Operation, Lamp Replacement (One Light per Lamp)\u003cbr\u003e: Â 65 lbs 30W 15W 10.6W 5.3W 88 uW\/cm2 at 3 feet 8,000+ Hours 254nm T8 1.5F G13 - 360Âº Flood PolishedLED Indicator Lights In Operation, Lamp Replacement (One Light per Lamp) Limit  Switch Yes MERV 16 0.3 to 1.0 Microns 72 cubic ft\/minute 54 cubic ft\/minute 3,240 cubic ft\/hour 1,080 cubic ft 810 cubic ft 648 cubic ft 540 cubic ft - 304 Stainless Steel, Aluminum Free Standing and Wall,  Surface, or Ceiling Mount  Louvered Exhaust Panel  15' 16\/3 SOOW Cord w\/ 120V Cord Cap 5-15 Straight, L5-15 Twist, or Pigtail info@purilite.ca\u003cbr\u003eSafety Switch:  Limit  Switch\u003cbr\u003eFilter:  Yes\u003cbr\u003eFilter MERV Rating:  MERV 16\u003cbr\u003eFilter Particulate Size:  0.3 to 1.0 Microns\u003cbr\u003eBlower Capacity:  72 cubic ft\/minute\u003cbr\u003eNominal Fixture Capacity:  54 cubic ft\/minute\u003cbr\u003eMax Treatment Capacity:  3,240 cubic ft\/hour\u003cbr\u003eMax Room Size @ 3 Air Changes\/Hour:  1,080 cubic ft\u003cbr\u003eMax Room Size @ 4 Air Changes\/Hour:  810 cubic ft\u003cbr\u003eMax Room Size @ 5 Air Changes\/Hour:  648 cubic ft\u003cbr\u003eMax Room Size @ 6 Air Changes\/Hour:  540 cubic ft\u003cbr\u003eAmps:  0.25A @ 120V\u003cbr\u003eAmbient Operating Temp Range:  -\u003cbr\u003eMaterials:  304 Stainless Steel, Aluminum\u003cbr\u003eMounting:  Free Standing and Wall,  Surface, or Ceiling Mount\u003cbr\u003eAir Flow Exit:   Louvered Exhaust Panel\u003cbr\u003eCord:   15' 16\/3 SOOW Cord w\/ 120V Cord Cap\u003cbr\u003eCord Cap:  5-15 Straight, L5-15 Twist, or Pigtail\u003cbr\u003e","brand":"Larson Electronics","offers":[{"title":"Default Title","offer_id":38308257923253,"sku":"PL3-IND-AHF-BX-UVC-R1-120V-15C","price":8344.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-IND-AHF-BX-UVC-R1-120V-15C-1.jpg?v=1611193697","url":"https:\/\/getcahits.com\/zh\/products\/pl3-ind-ahf-bx-uvc-r1-120v-15c","provider":"PuriLite","version":"1.0","type":"link"}