{"product_id":"pl3-halp-emg-48-2l-113","title":"Class 1 Division 2 Emergency ONLY Fluorescent Light - 4' 2 Lamp Emergency Fixture","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eHALP-EMG-48-2L-113\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eU.L. Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eUL Listing: United States - Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I Division 2, Groups A, B, C and D \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Type: Fluorescent \u003c\/td\u003e\n\u003ctd\u003eClass II, Division 2, Groups F, G \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: W-8.25 \" L-52\" H-7\"\u003c\/td\u003e\n\u003ctd\u003eUL 844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 8 Lbs \u003c\/td\u003e\n\u003ctd\u003eUL 924\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: Universal 120-277VAC 50\/60 hz\u003c\/td\u003e\n\u003ctd\u003eUL 8750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Watts: 64 Watts \u003c\/td\u003e\n\u003ctd\u003eUL 1598A Marine Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lumens T8 Bulbs: 5,900\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminous Efficacy F17-T8 Bulbs: 92 Lm\/W\u003c\/td\u003e\n\u003ctd\u003eCSA 22.2 No. 137-M81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Lamp Life Expectancy: 24,000+ Hours\u003c\/td\u003e\n\u003ctd\u003ecUL Listed for Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Temp: 4100K\u003c\/td\u003e\n\u003ctd\u003eMeets USCG Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBeam Angle: 150Ã‚Â°\u003c\/td\u003e\n\u003ctd\u003eT4 Temperature Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eAmbient Operating Temp Range:-30Ã‚Â°C to +70Ã‚Â°C\u003c\/td\u003e\n\u003ctd\u003eSwitch Leg for Powering Light On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eOperating Temp Range: T4C rated\u003c\/td\u003e\n\u003ctd\u003eIP66 Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMounting:Ã‚Â Flange Type - Stainless SteelÃ‚Â \u003c\/td\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eWiring Hub:Ã‚Â 1\/2\" or 3\/4\" Threaded NPT Hubs\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBattery Backup:Ã‚Â 90 minute runtime at 900 lumens\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eU.L Approval:Ã‚Â Ã‚Â Ã‚Â \n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eÃ‚Â \u003c\/td\u003e\n\u003ctd\u003eIntl:Ã‚Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eÃ‚Â \u003c\/td\u003e\n\u003ctd\u003eFax:Ã‚Â 1-903-498-3364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 160px;\"\u003e\nMade in the USA\nThe Larson Electronics HALP-EMG-48-2L-113 Hazardous Area Emergency Only Fluorescent Light Fixture is U.S.\/Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime.\nThe HALP-EMG-48-2L-113 hazardous area emergency fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated emergency light fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-48-2L-113 also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. \nThis emergency backup only fluorescent light works, mounts and is wired like our HALP-48-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will illuminate only when there is a loss of power, and will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on\/off without kicking the unit into emergency mode. \n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 171px;\"\u003e\n\u003ctable height=\"141\" width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 37%; height: 112px;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 26%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 37%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClick Photo to Enlarge \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 398px;\"\u003e\nNOTE ON LAMPS: This fixture comes equipped with F32-T8\/841 lamps.. \nStandard Flange Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 36 9\/16 inches on center apart along the top of this hazardous location light. The mounting holes are 7 inches on center across the top of the light.\nSuggested Applications: The HALP-EMG-48-2L-113 is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent\/cleaning areas, water treatment areas, processing plants and marine loading docks.\n\n\u003ctable cellpadding=\"2\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 28px;\"\u003eMade in USA Quality\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003eLamp Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 167px;\"\u003e\n1. Each unit dialectically tested.\n2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface.\n3. Fixture housing constructed of glass fiber reinforced polyester.\n4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps.\n5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection.\n6. 1\/2\" or 3\/4\", threaded access hole for wiring conduit. \n\n\u003c\/td\u003e\n\u003ctd\u003e\nF32-T8\/841 Ã¢â‚¬â€œ 2950 lumens per bulb, 24,000 hours life, 4100 Kelvin color \n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38276219961525,"sku":"PL3-HALP-EMG-48-2L-113","price":1866.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-HALP-EMG-48-2L-113.jpg?v=1629080770","url":"https:\/\/getcahits.com\/zh\/products\/pl3-halp-emg-48-2l-113","provider":"PuriLite","version":"1.0","type":"link"}