{"product_id":"pl3-eps-tps-16a","title":"16A Explosion Proof Manual Starter Switch - Class I, II, III - 600V Rated - Thermal Overload Protect","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\r\n\r\n\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe EPS-TPS-16A from Larson Electronics is an Explosion Proof Manual Starter Switch that is suitable for Class I, II and III flammable environments. Equipped Class 10 thermal overload protection, this 16-amp unit is rated at 600V AC. The explosion proof switch is constructed of malleable Aluminum and is offered in feed-through or dead-end configurations, with 1\/2\" NPT or 3\/4\" NPT hubs.\nThe EPS-TPS-16A is an explosion proof switch designed for applications in combustible work environments. Capable of handling loads up to 16 amps, this 2-pole unit is rated at 600V AC. Thermal overload protection is provided by a Class 10 Ambient-Compensated Thermal Overload Relay. This feature enables temporary overload at startup, with a Class 10 rating providing up to 10 seconds of overload condition before tripping the circuit. Ambient compensation reduces the possibility of false tripping, by taking the ambient temperature into consideration.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 171px;\"\u003e\n\u003ctable width=\"100%\" height=\"161\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 38%; height: 141px;\"\u003e\n \u003c\/td\u003e\n\u003ctd style=\"width: 33%;\"\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\nClick Photo to\nEnlarge\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 244px;\"\u003e\nThe\nEPS-TPS-16A explosion proof switch cover and housing box is constructed of\nmalleable aluminum with all arcing devices contained within an explosion proof\nlabyrinth switch for the highest protection possible. The entire unit is triple\ncoated with zinc electroplate, chromate, and a final epoxy powder coat for\nmaximum durability and corrosion resistance. A bushing seal at each conductor opening prevents damage to\nwiring insulation and a triple coat housing finish provides rugged protection\nagainst corrosion. \nHubs: This explosion proof unit is offered with 1\/2\" NPT or 3\/4\" NPT hubs. NPT tapped conduit openings are provided on the top and bottom of the unit in\nfeed through versions, while dead end versions have a single conduit hub,\nproviding easy and secure connection to main power line supplies. Each hub opening is fitted\nwith an integral bushing to prevent fraying or damage to insulation.\nMounting: Two\nexternal mounting lugs provide simple and secure mounting of the unit to walls\nand flat surfaces. The unit box, switch and face plate are all included with\nthe product. \nSuggested Applications: Manufacturing,\nIndustrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where\nCombustible Dust is Present.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 370px;\"\u003e\n\n\nSpecifications \/ Additional\nInformation \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEPS-TPS-16A Explosion Proof\nManual Switch\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eListing: United States, Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I, Division 1\u0026amp;2 Groups C,D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\nDimensions: 3.00\"-W X 4.69\"-D X\n6.13 \"-L\u003c\/td\u003e\n\u003ctd\u003eClass II, Division 1\u0026amp;2 Groups E,F,G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight:  -\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating: 600V AC, 1PH\u003c\/td\u003e\n\u003ctd\u003eNEMA 7 (C,D) 9 (E,F,G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps: 16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles: 2P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP: 1HP @ 230V AC, 1HP @ 120V AC; 3\/4 HP @ 115V DC, 3\/4 HP @ 230V DC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation: Toggle\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection:  Class 10 Ambient-Compensated Thermal Overload Relay\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation: Integral Bushings in Conductor Openings\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Materials: Box\/Receptacle- Malleable Aluminum, Sealing\nChamber-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Triple-coatâ‚¬â€Zinc Electroplate, Chromate, Epoxy Powder Coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting: External Mounting Lugs on Body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding: Single Internal Housing Ground Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 16px;\"\u003eConfiguration: Feed Through or Dead End\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 13px;\"\u003eHub Size Options: 1\/2\" NPT or 3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nScroll Down to Purchase-Â  \n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38354715410613,"sku":"PL3-EPS-TPS-16A","price":1332.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPS-TPS-16A.jpg?v=1628472805","url":"https:\/\/getcahits.com\/zh\/products\/pl3-eps-tps-16a","provider":"PuriLite","version":"1.0","type":"link"}