{"product_id":"pl3-epo-icb-b-480v-3w4p-60a","title":"Explosion Proof Receptacle - Class I, II, III - 60A, 480V - Circuit Breaker Switch, Aux Contacts - NEMA","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEPO-ICB-B-480V-3W4P-60A Explosion Proof Receptacle\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing: NRTL Listed for United States, Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I, Divisions 1 \u0026amp; 2 Group B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eDimensions:Â 15 7\/8\" x 5 3\/4\" x 9 3\/8\"\u003c\/td\u003e\n\u003ctd\u003eClass 1, Zones 1 \u0026amp; 2 IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 29 lbs\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2 Group F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eVoltage Rating: 480V AC\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating: 60 Amps\u003c\/td\u003e\n\u003ctd\u003eNEMA 3, 4, 4X 7(B,C,D), 9(F,G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP:  15HP @ 480V 1PH, 25HP @ 480V 3PH\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: 3-Pole, 4-Wire\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection: On\/Off Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAux Contact: Late-make Early-break, Rated @ 10A, 1\/3 HP 125\/250V AC\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: Copper Free Aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Electrostatically Applied Polyester\/Epoxy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: Wall\u003c\/td\u003e\n\u003ctd\u003eToll Free:Â 1-800-369-6671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring: Regular Stranding #10 Maximum\u003c\/td\u003e\n\u003ctd\u003eIntl:Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Configuration: Feed Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Size: 1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EPO-ICB-B-480V-3W4P-60A Explosion Proof Receptacle is approved for Class I, Division 1 \u0026amp; 2, Class II, Division 1 \u0026amp; 2 and Class III sites and provides a safe and secure power connection for portable or stationary electrical devices and equipment in hazardous locations. This 3-pole, 4-wire unit is constructed of copper-free aluminum and operates with 480V AC. Rated at 60 amps, the device can be used in Class I, Group B rated locations.\nThe explosion proof power receptacle is designed for use in combustible work sites, including Class I, Group B. This 60-amp receptacle features compatibility with 480V AC. The 3-pole, 4-wire unit is constructed of copper-free aluminum with an electrostatically applied polyester\/epoxy finish and contains an integral circuit breaker which provides short circuit and thermal overload protection as well as manually operable protection during connection and disconnection of electrical cables. This unit is easily wall mounted via two screw slot tabs at the side of the housing and contains a feed-thru configuration with 1\" NPT hub size. \nIntegral circuit protection: This unit contains a circuit breaker to allow safe, 60 amp at 480V AC max operation. The circuit breaker also gives protection against short circuits and provides added thermal time delay overload protection. The plug and receptacle contacts cannot be made or broken under load. When the plug is inserted, the plug and receptacle contacts engage before the switch closes. When the plug is withdrawn, the switch opens before the plug and receptacle contacts disengage. This provides the maximum safety of a dead front receptacle. Arcing is isolated in a flame and dust-tight chamber. No special interlock device or manual switch, operators simply pull the plug straight out.\nInterchangeability: The receptacle is fully interchangeable with configured and certified to UL1686 devices, such as Crouse-HindsÂ® ArktiteÂ® or AppletonÂ® PowertiteÂ®. Standard location receptacle bolt hole patterns match competitive back boxes so users can perform upgrades without changing back boxes in instances where changing the conduit system is difficult.\nSuggested Applications: Manufacturing, Industrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where Combustible Dust is Present.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40711832076469,"sku":"PL3-EPO-ICB-B-480V-3W4P-60A","price":7300.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPO-ICB-B-480V-3W4P-60A.jpg?v=1628473784","url":"https:\/\/getcahits.com\/zh\/products\/pl3-epo-icb-b-480v-3w4p-60a","provider":"PuriLite","version":"1.0","type":"link"}