{"product_id":"pl3-epo-2g-2x20a","title":"Class 1 Div 1 and Class 2 Div 1 - 2 Gang Outlet Box - Double Gang","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEPO-2G-2X20A Explosion Proof Power Outlet \u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eCertifications - Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eUnit Dimensions: 6.19\"-W X 5.69\"-D X 6.13\"-H\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eU.L.-Standard: No.-22.2,25,C22.2,30,C22.2,42,C22,159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle Current Rating: 2X20 Amp \u003c\/td\u003e\n\u003ctd\u003eU.L Listed.- E10784, E81751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: 3 Pole 2 Wire\u003c\/td\u003e\n\u003ctd\u003eCSA Standard: C22.2 No. 182.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 17px;\"\u003eOutlet Configuration: 5-15, 5-20, or 6-20 Straight Blade\u003c\/td\u003e\n\u003ctd\u003eCSA Certified: 065179\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles: 3\u003c\/td\u003e\n\u003ctd\u003eNEMA 3, 3R, 7CD, 9FG \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Openings: 1\/2\" oe 3\/4\"\u003c\/td\u003e\n\u003ctd\u003eClass 1, Division 1 Groups C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMating Plugs: ****, **** \u003c\/td\u003e\n\u003ctd\u003eClass 1, Division 2 Groups C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding: Housing \u003c\/td\u003e\n\u003ctd\u003eClass 2 Division 1 \u0026amp; 2 Groups F, G; Class 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eUnit Materials:Â  Box- Iron \/Receptacle- Copper Free Aluminum (4\/10 of 1% max.)\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eFinish: Box-Triple Coat \/ Receptacle-Expoxy Powder Coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eInsulating Blocks: Fiber Glass Reinforced Polyester\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\u003c\/td\u003e\n\u003ctd\u003eToll Free:Â 1-800-369-6671\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\u003c\/td\u003e\n\u003ctd\u003eIntl:Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EPO-2G-2X20A explosion proofÂ 2 gang powerÂ outlet provides durable and secure, weatherproof, multiple power connections for portable or stationary electrical devices and equipment in locations where equipment is susceptible to wet and corrosive environments.\nThis 2 gang power receptacle is ideal for operators seeking a high quality, wet area rated power receptacle suitable for use in industrial and manufacturing applications. This unit`s power receptacles are constructed of copper free aluminum and the housings are malleable iron. The unit is factory sealed and any arcing is safely contained with the interior of the receptacles. The receptacle contacts are deep recessed to avoid accidental contact and will accept standard non explosion proof plugs that are NEMA 5-20R, or 6-20R compatible although explosion proof plugs must be used to preserve explosion proof approval in hazardous environments. Ordinary location plugs will NOT activate these explosion proof receptacles. The iron housings are finished in a triple-coat zinc electroplate, chromate and epoxy powder coat while the receptacles are finished with an expoxy powder coat. This unit is designed to withstand wet and corrosive conditions such as those found in docks and shipyards and comes with spring loaded receptacle doors to prevent ingress of water and contaminants when the unit is not in use.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 171px;\"\u003e\n\u003ctable height=\"161\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 141px;\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClick Photo to Enlarge\u003c\/td\u003e\n \u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 402px;\"\u003e\nThe EPO-2G-2X20A 2 gang power receptacle is constructed of non sparking aluminum and finished with an epoxy powder coating while the housing is constructed of triple coated malleable iron for durability and added corrosion resistance. The internal receptacle plug contacts are constructed of brass and designed to maintain constant pressure along their entire length for superior connectivity. The plug receptacles are deeply recessed to prevent accidental contacts and designed for twist lock plug insertion to provide secure connections. A neoprene seal fitted inside the connector receptacles seals against the plug when inserted to provide positive sealing against water ingress. Spring loaded receptacle doors provide an automatic weather-tight seal when the plug is removed. In standard installations within the hazardous location area, threaded rigid pipe is brought to the outlet and the outlet is affixed to a mounting surface.Â  This 2 gang outlet is a mate for the Larson Electronics  and  explosion proof plugs and is compatible with all the Larson Electronics explosion proof lights we make with an explosion proof plug. \nOptions: This unit is available in a feed through or dead end options. The feed through option includes a 1\/2\" hub on either end of the receptacle and allows the source to power the receptacles while wired through the unit. The dead end option terminates the current at the receptacles. Please choose your option below. \nCircuit breaking protection: This unit`s receptacles are designed to safely contain any arcs between the internal contacts that may be created within the receptacle housing. \nInter-Compatibility: These units are compatible with Crouse Hindâ€žÂ¢ plugs under catalogue number \"ENP5151\" and Hubble-Killark AcceptorÂ® plugs under catalogue number \"UGP-20231\" and \" UGP-20232\". Due to possible manufacturer changes we cannot guarantee interchangability although we have made every effort to ensure cross compatibility correctness. \nSuggested Applications: Areas Where Ignitable Vapors Or Gases May Be Present, Manufacturing, Industrial, Commercial, Docks, Shipyards, Shipping Ports and other similar ship to shore applications as well as any application requiring a wet area suitable and highly durable source of secure power connection. \n\n\u003ctable cellpadding=\"2\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 28px;\"\u003eFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 155px;\"\u003e\n1. Specially designed receptacles contain arcs within the unit. \n2. Spring loaded doors seals receptacles when not in use. \n3. Brass contacts provide constant pressure and superior conductivity. \n4. Accepts non explosion proof plugs that are NEMA 5-20R, or 6-20R compatible. \n5. Neoprene seal compressed by plug prevents water ingress into receptacle when in use. \n6. Each receptacle rated to handle loads up to 20 Amps.\n7. Receptacles Epoxy powder coat finish for durability. Housing Triple coated for durability\/corrosion resistance. \n8. Compatible with Crouse Hindâ€žÂ¢ \"ENP5151\" and Hubble-Killark Acceptorâ€žÂ¢ \"UGP-20231,UGP-20232 \" plugs. \n9. Corrosion resistant and suitable for use in wet locations.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40711808352437,"sku":"PL3-EPO-2G-2X20A","price":1796.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPO-2G-2X20A.jpg?v=1628473383","url":"https:\/\/getcahits.com\/zh\/products\/pl3-epo-2g-2x20a","provider":"PuriLite","version":"1.0","type":"link"}