{"product_id":"pl3-epl-emg-48-2l-led-c","title":"Larson 48W Explosion Proof LED Light w\/ Emergency Backup - C1D1 - (2) 4ft LED Lamps - Blackout Light","description":"\u003cstrong\u003ePuriLite suggests you place an order directly with us for large Larson orders due to the potential customization requirements. Please call us at 1(647) 254-9757 to place your order. If you prefer to place your order online, a PuriLite agent will be in touch with you to discuss any custom options.\u003c\/strong\u003e\u003cbr\u003eThe Larson Electronics EPL-EMG-48-2L-LED-C Explosion Proof LED Light Fixture with red or blue lamps is NRTL Listed for United States and Canada approved Class I, Division 1 \u0026amp; 2 and Class II, Division 1 and 2 for areas where flammable chemical\/petrochemical vapors exist or have the potential to exist. Equipped with a 90-minute emergency backup feature, this 4` explosion proof LED light has a T6 temperature rating and carries a paint spray booth light certification, making it ideal for applications such as paint booths, oil rigs, offshore applications, petrochemical, manufacturing, chemical storage, water treatment centers, and food processing plants.\r\u003cbr\u003eThis 4' two lamp LED fixture is ideal for operators seeking a top quality explosion proof light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The 48-watt lighting system is equipped with Larson Electronicsâ€™ specially designed LEDST-5 bulbs, with two blackout red or blue LED lamp with 6 individual LED light strips in each side. Each lamp has individual leads to be powered separately. Our LED-T series bulbs are visibly brighter than standard F17\/T8`s and have consistently surprised many of our customers with their unexpectedly high light output levels.\r\u003cbr\u003eThese LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. This LED light, with a total of 48 watts, draws only 0.4 amps at 120 volts AC. The EPL-EMG-48-2L-LED-C is universal voltage, not multi-tap, and operates on any voltage from 120V to 277V AC 50\/60hz without any modifications. We also make a 10-30V DC version for low voltage applications for AC or DC power.\r\u003cbr\u003eThis fixture carries a T6 temperature rating and is approved for Class I Division 1, Groups C and D, Class I, Division 2, Group A, B, C and D, and Class II, Division 1 and 2, Groups E, F and G environments where flammable or combustible gases, vapors, dusts, fibers, and flying exist or stand the potential to exist. This LED linear fixture is approved for use in confined spaces.\r\r\u003cbr\u003e\u003cstrong\u003eLED Benefits:\u003c\/strong\u003e\r\u003cbr\u003eWe have eliminated the ballast box normally associated with explosion proof fluorescent fixtures which reduces overall weight and overall complexity of installation. There is no ballast in this unit and the included LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. These fluorescent LED lamps have internal drivers, eliminating external power components. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. This second generation lamp is offered in 600-675nm wavelength red or blue for the blackout lamp.\r\u003cbr\u003eUnlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the \"tube\" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting.\r\u003cbr\u003eEmergency Backup:\r\u003cbr\u003eThis emergency backup LED light contains a battery backup unit that adds emergency light functionality to the fixture. With an integrated emergency ballast, this explosion proof LED light will continue to operate one LED lamp for 90 minutes at 1,500 lumens after the main electrical power to the light is severed. Once standard electrical power is restored, the emergency battery pack will be recharged. The battery backup unit includes a switched leg for turning the light fixture on\/off without kicking the unit into emergency mode.\r\u003cbr\u003eEnergy Consumption Comparison\r\u003cbr\u003eT5HO\r\u003cbr\u003eT8\r\u003cbr\u003eLED\r\u003cbr\u003eWattage\r\u003cbr\u003e48 watts\r\u003cbr\u003e34 watts\r\u003cbr\u003e28 watts\r\u003cbr\u003eAmp Draw @ 120V AC\r\u003cbr\u003e0.40 amps\r\u003cbr\u003e0.29 amps\r\u003cbr\u003e0.23 amps\r\u003cbr\u003eAmp Draw @ 220V AC\r\u003cbr\u003e0.22 amps\r\u003cbr\u003e0.16 amps\r\u003cbr\u003e0.13 amps\r\u003cbr\u003eAmp Draw @ 240V AC\r\u003cbr\u003e0.20 amps\r\u003cbr\u003e0.14 amps\r\u003cbr\u003e0.12 amps\r\u003cbr\u003eAmp Draw @ 277V AC\r\u003cbr\u003e0.18 amps\r\u003cbr\u003e0.13 amps\r\u003cbr\u003e0.10 amps\r\u003cbr\u003eLamp Life Expectancy\r\u003cbr\u003e20,000 hours\r\u003cbr\u003e24,000 hours\r\u003cbr\u003e50,000 hours\r\u003cbr\u003eOperation cost per year\r\u003cbr\u003e$25.23\r\u003cbr\u003e$14.87\r\u003cbr\u003e$14.72\r\u003cbr\u003eOur EPL-EMG-48-2L-LED-C LED light fixture is NRTL Listed for United States and Canada approved for use in paint spray booths. Please note, according to the NEC, using threaded rigid pipe does not require additional seal offs with this fixture. An EYM and seal off is necessary for flex conduit or other non-rigid pipe implementations.\r\u003cbr\u003eMounting Options:\r\u003cbr\u003eUnless otherwise specified, our standard, most popular configuration is the bracket end mounting shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations.\r\u003cbr\u003eSurface Mount (Standard)\r\u003cbr\u003eAdjustable Surface Mount Brackets:\r\u003cbr\u003eEach bracket is cinched to the bracket mounting peg on each side of the light. The angle of the bracket is set by tightening two cap screws on either side of the bracket. The cap screws act as a set screw. The bracket itself is mounted via a single bolt hole at the top the bracket. There are two brackets, one on each end of the light. Once the brackets are mounted to a surface (ceiling, floor or wall), the light fixture can be removed from the brackets by loosening the cap screws that hold the bracket to the mounting peg.\r\u003cbr\u003ePendant Mount (Optional)\r\u003cbr\u003e3 Conduit Positions\r\u003cbr\u003e\u003cstrong\u003eSuspension Mounting:\u003c\/strong\u003e\r\u003cbr\u003ePendant mount fixtures hang from the ceiling and are suspended by rigid pipe. Each fixture features a 1\/2â€ NPT junction box on one end, and a 1\/2â€ NPT adjustable L-bracket on the other end of the fixture. Operators bring rigid pipe down to the threaded mounting hubs. Wiring is fed down through the rigid pipe to the junction box and tied in to the fixtureâ€™s lead wires, completing the electrical connection. The adjustable L-shape mounting bracket provides support for the opposite end of the fixture.\r\u003cbr\u003e\u003cstrong\u003eSuggested \u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/strong\u003e\r\u003cbr\u003ePaint spray booths, aircraft maintenance, oil drilling rigs, refineries, solvent and cleaning areas, gas processing plants, chemical manufacturing, waste treatment plants, gas processing plants.\r\u003cbr\u003eContact info@purilite.ca\r for more information about our custom options tailored to meet your specific industry needs.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eNRTL Listed for United States \u0026amp; Canada\u003cbr\u003eUnited States \u0026amp; Canada NRTL Listed forÂ \u003cbr\u003eDimensions: W-11.25\" x L-52\" x H-8.5\"\u003cbr\u003eWeight: 45 lbs\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e  Universal 120-277V AC 50\/60 Hz or 10-30V DC120-277V AC 60Hz\u003cbr\u003eTotal Watts: 48W (24W per Lamp)\u003cbr\u003eTotal Lumens: 3,000 \u003cbr\u003eLED Lamp Life Expectancy:  50,000+ Hours\u003cbr\u003eLuminous Efficiency:  125 Lumens per Watt\u003cbr\u003eColor:  600-675Nm (Red) or 420-440Nm (Blue)\u003cbr\u003eColor Rendering Index:  \u0026gt;80\u003cbr\u003eBeam Angle:  150Â°\u003cbr\u003ePower Efficiency:  90%\u003cbr\u003ePower Factor:  \u0026gt;0.95\u003cbr\u003eAmp Draw:  0.4A @ 120V AC, 0.173A @ 277V AC\u003cbr\u003eAmbient Operating Temp Range: -35Â° C to +55Â°C\u003cbr\u003eOperating Temp Rating:  T6 Rated\u003cbr\u003eMinimum Operating Temp:  -35Â°C\u003cbr\u003eMaximum Case Temp:  +90Â°C\u003cbr\u003eHousing Material:  Cast Aluminum End Caps, Aluminum Reflectors - Copper Free\u003cbr\u003eLens Material:  Hardened Borosilicate Glass Tubes\u003cbr\u003eGasket Material:  Buna Rubber O-Rings\u003cbr\u003eMounting:  Surface Standard - Pendant Optional\u003cbr\u003eWiring Hub:  1\/2\" NPT\u003cbr\u003eBattery AC Input \u003cstrong\u003eVoltage:\u003c\/strong\u003e 120-277V AC 60Hz\u003cbr\u003eBattery AC Input Current:  90 mA\u003cbr\u003eBattery AC Input Power Rating:  9.5W\u003cbr\u003eBattery AC Output Current:  120V @ 165mA - 277V @ 72mA\u003cbr\u003eIllumination Time:  90 Minutes\u003cbr\u003eBattery Type:  High Temp, Maintenance Free, Nickel Cadmium\u003cbr\u003eBattery Lifespan:  7 to 10 Years\u003cbr\u003eBattery Charge Current:  250 mA\u003cbr\u003eBattery Recharge Time:  24 Hours\u003cbr\u003e","brand":"Larson Electronics","offers":[{"title":"Default Title","offer_id":38385273241781,"sku":"PL3-EPL-EMG-48-2L-LED-C","price":7796.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPL-EMG-48-2L-LED-C-1.jpg?v=1611971049","url":"https:\/\/getcahits.com\/zh\/products\/pl3-epl-emg-48-2l-led-c","provider":"PuriLite","version":"1.0","type":"link"}