{"product_id":"1-phase-buck-boost-step-up-transformer-120-240v-primary-110-220v-secondary-9-17-amps-50-60hz","title":"1-Phase Buck\/Boost Step-Up Transformer - 120\/240V Primary - 110\/220V Secondary - 9.17 Amps - 50\/60Hz","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 58.4974%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMT-BBT-120.240V-110.220V-2P-9.17A Buck and Boost Step-Up Transformer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.5026%;\"\u003e\u003cspan\u003e\u003cstrong\u003eRatings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransformer Type:\u003c\/strong\u003e Buck\/Boost Step-Up Transformer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL listed for United States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransformer Configuration:\u003c\/strong\u003e Boost\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA certified for Canada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase:\u003c\/strong\u003e Split Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 3R Indoor\/Outdoor Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeets or Exceeds NEMA ST-20 Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120\/240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuck and Boost Step-Up Transformer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Amps:\u003c\/strong\u003e 8.33 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Configuration:\u003c\/strong\u003e Two winding\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ekVA:\u003c\/strong\u003e 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 110\/220 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Amps:\u003c\/strong\u003e 9.17 A @ 220 V; 4.59 A @ 110 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage % Difference:\u003c\/strong\u003e -\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Configuration:\u003c\/strong\u003e Two winding\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWinding Material:\u003c\/strong\u003e Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKnockouts:\u003c\/strong\u003e Side and rear\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Termination:\u003c\/strong\u003e Front access copper tabs or lead wires\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Termination:\u003c\/strong\u003e Front access copper tabs or lead wires\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e Air \/ Dry Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 130°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Rise:\u003c\/strong\u003e 80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSound Level:\u003c\/strong\u003e 36 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 3R\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEncapsulation:\u003c\/strong\u003e Silica sand, resin compounds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFinish:\u003c\/strong\u003e ANSI 61 Grey \/ UL50\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Wall mount via mounting tabs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 7.19\"H x 8.62\"W x 5.56\"D\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 26.6 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 class=\"product-page-header\" itemprop=\"name\"\u003e1-Phase Buck\/Boost Step-Up Transformer - 120\/240V Primary - 110\/220V Secondary - 9.17 Amps - 50\/60Hz\u003c\/h1\u003e\n\u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable border=\"0\" width=\"550\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThe MT-BBT-120.240V-110.220V-2P-9.17A split phase step-up Buck and Boost Transformer from Larson Electronics is powerful, reliable, and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-BBT-120.240V-110.220V-2P-9.17A provides increased reliability, higher efficiency, protection against critical equipment failures and an extra level of protection by isolating the power source from the connected device. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransformer Features:\u003c\/strong\u003e The MT-BBT-120.240V-110.220V-2P-9.17A buck and boost transformer is a split phase unit with a 2 kVA rating and a primary voltage of 120\/240 V AC using a maximum of 8.33 amps on the primary side. This step-up transformer has a split phase secondary voltage of 110\/220 V and provides up to 9.17 amps (4.59 A at 110 V) on the secondary side. Featuring robust construction, this unit`s cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The NEMA 3R painted steel enclosure makes the unit suitable for both indoor and outdoor applications, and this step-up transformer can be either floor or wall mounted. The MT-BBT-120.240V-110.220V-2P-9.17A features a 130°C insulation with a 80°C temperature rise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e The aluminum winding in the MT-BBT-120.240V-110.220V-2P-9.17A are formed from high quality aluminum wire help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations. Buck and boost transformers are designed to maximize the performance and life of electrical equipment. The MT-BBT-120.240V-110.220V-2P-9.17A is encapsulated in silica sand and resin, and cased in a NEMA 3R steel enclosure. NEMA 4, NEMA 4X, and NEMA 12 enclosures are available upon request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBenefits:\u003c\/strong\u003e The MT-BBT-120.240V-110.220V-2P-9.17A buck\/boost step-up transformer offers many benefits to the consumer. Buck\/boost transformers pass the majority of the load voltage directly through the transformer, only transforming a small percentage of the load. Due to this technology, a smaller and quieter step-up transformer is manufacturered and uses less materials. This provides owners with significant energy savings as well as offering environmental benefits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHigher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Installation and maintenance costs are reduced due to the smaller form factor, and less overall space requiorments are decreased. In addition, these step-up transformers operate quieter than a standard autotransformer of the same capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Integrated wall mounting brackets make installation fast and easy. Because of the smaller overall footprint, heavy machinery is rarely needed for mounting and installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Installation is simple. Connect the primary leads and secondary leads to the step-up transformer per the provided wiring diagram. Knockout hubs on either side and the bottom of the transformer allow for easy line-in and line-out wiring. The front access cover provides convenient .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Air conditioners, lighting systems, heating elements, motor applications and other applications that that require the ability to power loads that differ from the available line voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLimitations:\u003c\/strong\u003e While there are many benefits to a buck\/boost transformer, there are some limitations to consider. This transformer will only transformer voltage, it will not convert phases, it will not create even legs between line 1 and line 2 (L1 and L2 WILL be UNEVEN), has no circuit isolation, and does not create a neutral for applications where a neutral is not already present. If any of these limitations apply to you, you will need a standard transformer. Please see below link for our standard line of \u003ca href=\"https:\/\/www.larsonelectronics.com\/category\/601\/industrial-transformers.aspx\"\u003eindustrial transformers\u003c\/a\u003e or our line of \u003ca href=\"https:\/\/www.larsonelectronics.com\/category\/1066\/phase-converters--single-to-three-phase.aspx\"\u003ephase converters\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote on Phases:\u003c\/strong\u003e This buck\/boost transformer is a single phase step-up transformers. For three phase transformers, click on the following links:\u003cbr\u003e\u003ca href=\"https:\/\/www.larsonelectronics.com\/category\/1080\/three-phase-delta-buck-and-boost-transformers.aspx\"\u003eThree Phase Delta Buck\/Boost Transformers\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.larsonelectronics.com\/category\/1081\/three-phase-wye-buck-and-boost-transformers.aspx\"\u003eThree Phase Wye Buck\/Boost Transformers\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":43329989214457,"sku":"PL3-MT-BBT-120.240V-110.220V-2P-9.17A","price":1034.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/223857_1.jpg?v=1664113189","url":"https:\/\/getcahits.com\/zh\/products\/1-phase-buck-boost-step-up-transformer-120-240v-primary-110-220v-secondary-9-17-amps-50-60hz","provider":"PuriLite","version":"1.0","type":"link"}