{"product_id":"pl3-mpd-cr1-tb-ye0ye-lz-m1","title":"Power Distribution Panel - 480Y\/277V 3-phase Panel - 100A MCB - (4) MCCB Breakers - Hinged Door","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eMPD-CR1-TB-YE0YE-LZ-M1 Power Distribution Panel\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eLine-in Cord: Not Included - Requires Minimum Use #2 THHN Cu @ [600V] (**Customer Provided**)\u003c\/td\u003e\n\u003ctd\u003eNEMA 2 Indoor Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eLine-in Cord Cap: Not Included - Requires Minimum Use Plug 100A @ [480Y\/277V] (**Customer Provided**)\u003c\/td\u003e\n\u003ctd\u003eMade in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Primary OCP: 100A @ 480V\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage: 480V AC, Wye\u003c\/td\u003e\n\u003ctd\u003ePowder Coat Finish Standards:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Phase: 3-phase\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-523\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Frequency: 60 Hz\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-3359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel: 100A 480\/277V 3-phase MCB N3R\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Breakers: (1) 100A 3P MCCB [480V]\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-3363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Protection: MCCB Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003eComplies with ASTM D-2794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransformer: -\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Breakers: (1) 60A 3P MCCB [480V], (1) 50A 3P MCCB [480V], (1) 30A 3P MCCB [480V]\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Protection: MCCB Circuit Breakers\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuits: -\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed Type: Bottom\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating: 14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature: 40Ã‚Â°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eMaterials: Steel, Copper\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Material: Copper\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Bar Material: Aluminum (Bolted)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Finish: High-strength TGIC Polyester Powder Coated Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor: Gray steel panel w\/ hinged door and locking access door handle, wall mounted, (4) bottom knock outs, w\/ external operator handles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Wire Size: 4-350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 48\" x 36\" x 12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight:  -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight: 200 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram.\u003c\/td\u003e\n\u003ctd\u003e*All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250*\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 39%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics MPD-CR1-TB-YE0YE-LZ-M1 Power Distribution Panel is designed for reliable, safe and convenient power distribution at industrial work sites. This 100-amp unit provides three-phase 480Y\/277V via a main circuit breaker panel. The power distribution panel provides operators the ability to safely tap into and distribute 480Y\/277V power from a variety of sources including generators and direct grid power. \n*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* \nThe MPD-CR1-TB-YE0YE-LZ-M1 power distribution panel provides a safe and reliable way for operators in industrial settings to tap into and utilize power sources independently of the work area. The PNL series of power distribution panels require operators to provide their own line-in cables for use. Knockouts located at the bottom of the unit are provided for convenient installation of operator-provided input and output cables. \nThe panel is designed to operate with three-phase 480Y\/277V voltage. Power distribution for this panel runs 480Y\/277V through a 100-amp main circuit breaker panel. The NEMA 3R 100-amp 480Y\/277V main circuit breaker panel is protected by one 100-amp 3-pole 480V molded case circuit breaker. This panel contains one 60-amp 3-pole 480V molded case circuit breaker, one 50-amp 3-pole 480V molded case circuit breaker and one 30-amp 3-pole 480V molded case circuit breaker. \n\nEnclosure Design: This power distribution system is housed in a space-saving enclosure and carries a NEMA 2 rating for protection against debris and ingress of water (dripping or minimal splashing) in indoor locations. A hinged door offers access to internal system components. The door handle is lockable using a key in order to deter the possibility of tampering. Protruding operator handles are available from the door, which allows individuals to use the panel with the door closed. \nThe power distribution system is constructed of steel with a polyester powder coated gray finish for durability against dirt, moisture and mild corrosion. This special coating creates a high-strength barrier for protection from accidental bumps and scratches. The TGIC polyester powder coat finish offers reliable resistance against chemicals, UV light (sun light) and degrading elements in outdoor locations. Our powder coating solution ensures robust color retention for many years without fading. Custom colors, such as blue (standard), black, desert tan or forest green, and galvanized finishes are available upon request. Non-standard powder coat colors or galvanized finishes may increase price and lead times. \nWe also offer similar power distribution panels on dolly carts with wheels, powder coated cube frames with lifting eyelets\/skid pockets or stand-alone with handles for faster turnarounds and completion of temporary tasks. \nCertification:  All units are built in accordance to NFPA 70 (National Electric Code). All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request.\nGrounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. \n~Please check all motor loads for dual rated motors that will work 208 or 240.~\nApplications: This power distribution system is NEMA 3R rated and ideal for indoor\/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, hazardous location operations, shows, exhibits, and shipyard operations. \n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38308259168437,"sku":"PL3-MPD-CR1-TB-YE0YE-LZ-M1","price":13280.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-MPD-CR1-TB-YE0YE-LZ-M1.jpg?v=1628906730","url":"https:\/\/getcahits.com\/products\/pl3-mpd-cr1-tb-ye0ye-lz-m1","provider":"PuriLite","version":"1.0","type":"link"}