{"product_id":"pl3-ind-hvac-act-r1-de-48-4l-xb","title":"Larson AC Coil Sanitation Bolt-in Kit - (4) 120W T8HO UV Lamps w\/ (1) PS - Mounting Hardware - Axial","description":"\u003cstrong\u003ePuriLite suggests you place an order directly with us for large Larson orders due to the potential customization requirements. Please call us at 1(647) 254-9757 to place your order. If you prefer to place your order online, a PuriLite agent will be in touch with you to discuss any custom options.\u003c\/strong\u003e\u003cbr\u003eThis unit is Made In USA - Manufactured in Texas\r\u003cbr\u003eThe IND-HVAC-ACT-R1-DE-48-4L-XB AC Coil Sanitation Bolt-in Kit from Larson Electronics  prevents bacterial and unwanted growth in AC condenser coils. AC cleaning is facilitated by four double-ended 48\" 120W T8HO UV lamps in an axial configuration. Mounting hardware, UV warning sticker and power supply are included with the kit.\r\u003cbr\u003e*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. \r\r\u003cbr\u003e*\r\u003cbr\u003eThe IND-HVAC-ACT-R1-DE-48-4L-XB is a powerful sanitation solution for AC condenser coil cleaning. This high output UV coil system projects ultraviolet rays inside the coil it is mounted in. The light prevents bacteria and other types of buildup from accumulating on the coil, resulting in cleaner air, less maintenance and better long-term HVAC performance. The bolt-in kit comes with mounting hardware needed during installation. This axial sanitation system can fit inside 8\" ducts.\r\u003cbr\u003eEquipped with four, 48\" double-ended T5HO UVC fluorescent lamps, this system offers 106.4 watts (26.6W per lamp) of UV output within the 200nm - 280nm UV-C range (254 nm). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The included power supply features an indicator light with an L-bracket for installation with the ballast. One UV warning label is available for installation outside of the HVAC system (extra stickers can be purchased at an additional cost). We offer optional vertical support kits for vertical lamp installations, as well as an optional UV shield for protection from UV rays and viewing port.\r\u003cbr\u003eBefore and After UV Treatment on AC Condenser Coils\r\u003cbr\u003eOperation:\r\u003cbr\u003eThe UV lamps must be installed inside the AC handling units. AC coils are known to be dark and humid, making them areas prone to bacterial growth, mold, mildew and other harmful  microbes. If left untreated, the microorganisms can cause diseases, allergies and  odors. The UV lights address these issues by eliminating growth from AC condenser coils and drain pans. This solution also reduces time spent and costs on HVAC maintenance.\r\u003cbr\u003eCable:\r\u003cbr\u003eThe IND-HVAC-ACT-R1-DE-48-4L-XB comes with a 10' cable and a 60' cable for connection to the ballast (one cable per lamp). The extended wiring for one lamp allows operators to install the lights with many different configurations for maximum coverage. For example, the lamps can be installed in a stacked configuration or in separate locations within the HVAC system. We offer units with cable strain relief, cable extensions, and a door interlock switch at an additional cost.\r\u003cbr\u003eMounting:\r\u003cbr\u003eThe IND-HVAC-ACT-R1-DE-48-4L-XB is designed to be secured on AC coils using included mounting hardware. Our mounting kit includes the following parts: (16) sheet metal screws, 1\/2\" pipe clamp, lamp mount clips, (8) stainless steel L-brackets and (16) black zip ties. We offer models with mounting magnets for seamless mounting, 12\" stand-off bracket and stainless steel tubing (may come with additional cost).\r\u003cbr\u003eNote on Environment:\r\u003cbr\u003eSunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.\r\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\r\u003cbr\u003eAC sanitation and disinfection.\r\u003cbr\u003eLarson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your \u003cstrong\u003eSpecifications\u003c\/strong\u003e. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1(647) 254-9757 or\r\u003cbr\u003eContact info@purilite.ca\r\u003cbr\u003eto discuss your specific requirements.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eLamp Technology:  UV-C Fluorescent\u003cbr\u003eLamp Quantity:   (4) UV Lamps\u003cbr\u003eLamp Dimensions:   48\"-L\u003cbr\u003eDuct Size:  8\"\u003cbr\u003eWeight:  -\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e  -\u003cbr\u003eTotal Watts:  480W\u003cbr\u003eSingle-lamp Watts:  120W\u003cbr\u003eTotal UV Output:  106.4W\u003cbr\u003eSingle-lamp UV Output:  26.6W\u003cbr\u003eUV Irradiance:  480 uW\/cm2 at 3 feet, \r\u003cbr\u003e            1,118.4 uW\/m2 @ 2 feet, \r\u003cbr\u003e            1,718 uW\/cm2 @ 18 inches, \r\u003cbr\u003e            2,568 uW\/cm2 @ 14 inches, \r\u003cbr\u003e            3,110.4 uW\/cm2 @ 12 inches, \r\u003cbr\u003e            3,811.2 uW\/cm2 @ 10 inches, \r\u003cbr\u003e            4,728 uW\/cm2 @ 8 inches, \r\u003cbr\u003e            6,192 uW\/cm2 @ 6 inches, \r\u003cbr\u003e            8,928 uW\/cm2 @ 4 inches, \r\u003cbr\u003e            10,944 uW\/cm2 @ 3 inches, \r\u003cbr\u003e            15,504 uW\/cm2 @ 2 inches\u003cbr\u003eExpected Lifespan:  8,000+ Hours\u003cbr\u003eUV Wavelength:  UV-C, 200nm - 280nm (254 nm)\u003cbr\u003eLamp Type:   Double-ended T8HO UV Lamp\u003cbr\u003eLamp Base:  G13\u003cbr\u003eReplacement Lamp:  FRL-48-1X-T8HO-120W-UV-C\u003cbr\u003eBeam Angle:  180Â°\u003cbr\u003eLight Configuration:  Flood\u003cbr\u003ePower Supply:  (1)  Included, Indicator Light w\/ L-bracket \u003cbr\u003eLabels:  (1) UV Warning Label\u003cbr\u003eLayout:  Axial\u003cbr\u003eAmps:  -\u003cbr\u003eAmbient Operating Temp Range:  -\u003cbr\u003eMaterials:  Stainless Steel \u003cbr\u003eMounting:  (16) Sheet Metal Screws, 1\/2\" Pipe Clamp, Lamp Mount Clips, (8) Stainless Steel L-brackets, (16) Black Zip Ties\u003cbr\u003eCable:  (1) 10' and (1) 60' Cables - Lamps to Ballast\u003cbr\u003e","brand":"Larson Electronics","offers":[{"title":"Default Title","offer_id":38308240228533,"sku":"PL3-IND-HVAC-ACT-R1-DE-48-4L-XB","price":6422.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-IND-HVAC-ACT-R1-DE-48-4L-XB-1.jpg?v=1611193232","url":"https:\/\/getcahits.com\/products\/pl3-ind-hvac-act-r1-de-48-4l-xb","provider":"PuriLite","version":"1.0","type":"link"}