{"product_id":"pl3-halp-emg-24-2l-bx","title":"Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eHALP-EMG-24-2L\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eU.L. Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eUL Listing: United States - Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I Division 2, Groups A, B, C and D \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Type: Fluorescent \u003c\/td\u003e\n\u003ctd\u003eClass II, Division 2, Groups F, G \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: W-8.25 \" L-26\" H-7\"\u003c\/td\u003e\n\u003ctd\u003eUL 844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 5 Lbs \u003c\/td\u003e\n\u003ctd\u003eUL 924\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: Universal 120-277VAC 50\/60 hz\u003c\/td\u003e\n\u003ctd\u003eUL 1598A Marine Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Watts: 80 watts \u003c\/td\u003e\n\u003ctd\u003eCalifornia Title 24 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lumens T5-HO Bulbs: 5,300\u003c\/td\u003e\n\u003ctd\u003ecUL Listed for Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminous Efficacy T5-HO Bulbs:: 66.25 Lm\/W\u003c\/td\u003e\n\u003ctd\u003eMeets USCG Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Lamp Life Expectancy: 20,000+ Hours\u003c\/td\u003e\n\u003ctd\u003eT4 Temperature Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Temp: 4100K\u003c\/td\u003e\n\u003ctd\u003eSwitch Leg for Powering Light On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBeam Angle: 150Ã‚Â°\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eAmbient Operating Temp Range:-40Ã‚Â°C to +65Ã‚Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eOperating Temp Range:Ã‚Â T4A rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMounting: Surface Standard - Pendant Optional\u003c\/td\u003e\n\u003ctd\u003eToll Free:Ã‚Â 1-800-369-6671\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eWiring Hub: (2) 1\/2\" or 3\/4\" threaded NPT hubs\u003c\/td\u003e\n\u003ctd\u003eIntl:Ã‚Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBattery Backup: 90 minute runtime at 900 lumens\u003c\/td\u003e\n\u003ctd\u003eFax:Ã‚Â 1-903-498-3364\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eU.L Approval:Ã‚Â Ã‚Â Ã‚Â \u003c\/td\u003e\n\u003ctd\u003eE-mail:Ã‚Â \n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 160px;\"\u003e\nMade in the USA\nThe Larson Electronics HALP-EMG-24-2L-BX Hazardous Area Fluorescent Emergency Light Fixture is U.SÃ‚Â \/ Canada U.L approved Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4A temperature ratingÃ‚Â and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture uses Bi-Axial design bulbs to increase wattage and light output without increasing fixture size or weight.\nThe HALP-EMG-24-2L-BX hazardous area fluorescent emergency light fixture builds on the effectiveness of our HALP-24 series by including bi-axial lamps which raise the fixture`s wattage and light output totals without increasing the unit`s size or weight. Although some efficiency is sacrificed for increased output, this unit`s lower cost and increased ouput helps offset this lower efficiency. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. \nThe HALP-EMG-24-2L-BX also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. ThisÃ‚Â fixture ideal for hazardous areas where corrosion resistance is mandatory and space limitations require a powerful yet compact lighting solution.\nThis fluorescent light works, mounts and is wired like our HALP-24-2L-BX explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on\/off without kicking the unit into emergency mode.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 171px;\"\u003e\n\u003ctable height=\"141\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 37%; height: 112px;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 26%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 37%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eÃ‚Â Click Photo to Enlarge \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 398px;\"\u003e\nNOTE ON LAMPS: This fixture comes equipped with Bi-Axial Bulbs which increases the wattage of the standard HALP-EMG-24-2L from 34 watts with 2 standard T5-HO lamps to 80 watts with bi-axial bulbs. The HALP-24-2L-BX has an electronic universal ballast and works on 120-277VAC.\nSurface Mounting: Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91\" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5\" inches on center across the top of the light.\nPendant Mounting:Ã‚Â This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1\/2\" or 3\/4\" NPT hubs on either side of the Ã‚Â fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture.\nSuggested Applications:Ã‚Â The HALP-24-2L-BX is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent\/cleaning areas, water treatment areas, processing plants and marine loading docks.\n\n\u003ctable cellpadding=\"2\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 28px;\"\u003eMade in USA Quality\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003eLamp Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 167px;\"\u003e\n1. Each unit dialectically tested.\n2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface.\n3. Fixture housing constructed of glass fiber reinforced polyester.\n4. Relamping done via stainless steel snap locking latches, which enable the operator to remove the door and access the lamps.\n5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection.\n6. 1\/2\" or 3\/4\", threaded access hole for wiring conduit. \n\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38276206985397,"sku":"PL3-HALP-EMG-24-2L-BX","price":1816.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-HALP-EMG-24-2L-BX.jpg?v=1629080913","url":"https:\/\/getcahits.com\/products\/pl3-halp-emg-24-2l-bx","provider":"PuriLite","version":"1.0","type":"link"}