{"product_id":"pl3-halp-anc-48-2l-led","title":"Hazardous Location LED Light - C1D2\/C2D2 - Corrosion Resistant for Marine - Modbus TCP\/IP Network","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n \u003ctd style=\"width: 61%;\"\u003eHALP-ANC-48-2L-LED Hazardous Area LED Offshore Light\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Listing: United States - Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I Division 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: W-8.25\" x L-52\" x H-7\"\u003c\/td\u003e\n\u003ctd\u003eClass II, Division 2, Groups F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 8 Lbs \u003c\/td\u003e\n\u003ctd\u003eUL 844 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Watts: 56 watts (28 Watts Per Lamp) \u003c\/td\u003e\n\u003ctd\u003eUL 1598A Marine Type (Salt water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lumens: 7,000 (3,500 Per Lamp)\u003c\/td\u003e\n\u003ctd\u003eCalifornia Title 24 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: Universal 120-277VAC 50\/60 Hz or 12-24V AC\/DC\u003c\/td\u003e\n\u003ctd\u003eT4A Temperature Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Life Expectancy: 50,000 Hours\u003c\/td\u003e\n\u003ctd\u003eUSCG Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminous Efficacy: 120 Lumens per Watt\u003c\/td\u003e\n\u003ctd\u003ePassword Protected Network Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range: -30Ã‚Â°C to +85Ã‚Â°C\u003c\/td\u003e\n\u003ctd\u003eNo Programming Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Angle: 150Ã‚Â°\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Temp: 5600K or 4500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMinimum Operating Temp: -30 C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMaximum Case Temp: 90 C\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting: Flange Type Surface Mount or Pendant Mount\u003c\/td\u003e\n \u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Hub: 1\/2\" or 3\/4\" Threaded\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Controller Specs\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 1.41\" x 3.88\" x 3.1\"\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 5 oz\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type: 10\/100 Base-T Ethernet Port\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols: HTTP, XML, Modbus TCP\/IP\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply: 9-28V DC\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input: (1) Optically Isolated 4-26V DC\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent: 950uA @ 4V, 8.5mA @ 26V\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contacts: (1) SPDT - 240V AC\/30V DC Max @ 12A\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Modes: On\/Off or Pulsed\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Timer Duration: 0.1 to 86,400 Seconds\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Functions: Monitor, Local Relay Control, Remote Relay Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators: (4) Digital Input Voltage Applied, Relay Coil Energized, Network Linked, Network Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature: -40Ã‚Â°C to 57Ã‚Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material: Lexan 940 Polycarbonate Plastic\u003c\/td\u003e\n\u003ctd\u003eToll Free:Ã‚Â 1-800-369-6671\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: Surface, Wall or DIN Rail\u003c\/td\u003e\n\u003ctd\u003eIntl:Ã‚Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassword Protection: Yes @ Setup (Base 64 Encoding, 10 Characters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors: 3-position Removable (Relay- C, NO, NC), 5-position Removable (Power\/Input), 8-pin RJ-45 (Network)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\nMade in the USA \nThe Larson Electronics HALP-ANC-48-2L-LED Hazardous Area LED Light Fixture is a U.S.\/Canada UL Listed connected lighting solution for Class 1 Division 2 Groups A, B, C and D environments. Modbus TCP\/IP network capable, this hazardous location LED light has a T4 temperature rating and carries a United States Coast Guard approval, making it ideal for applications such as oil rigs, ships, offshore applications, petrochemical, manufacturing, chemical storage, and water treatment centers. Operators can setup remote access, controls and configurations using the Modbus TCP\/IP network controller (via a standard web browser). \nThis four foot long, two lamp connected LED fixture is ideal for operators seeking a top quality hazardous location light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The HALP-ANC-48-2L-LED hazardous area LED light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Eight corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. \nAevum Network Controlled Lighting Solution: The Aevum Network Controlled Lighting Solution from Larson Electronics enables connected and intelligent illumination using cutting-edge and existing networks. Using Modbus TCP\/IP or DALI (for fixtures with dimming features), businesses can seamlessly control lights and sensors from remote locations, without traditional light switches. Web-based panels facilitate real-time monitoring of connected equipment and allows operators to switch units on\/off, configure activation settings and more. Businesses may utilize their own systems and software with these controllers, ensuring robust flexibility and cost savings (no contracts). The Aevum Network Controlled Lighting Solution can improve productivity in the workplace by automating basic lighting controls and making lighting controls widely accessible in the facility, via local networks or the internet. Operators also have the option to monitor the status of fixtures from a remote location, which can improve maintenance and reduce downtimes. \nControls: Controls for the explosion proof LED fixture is accessible using a web-based control panel. Compatible with HTTP, XML, or Modbus TCP\/IP protocols, network configuration is accessible using web-based pages (no programming required). Operators can monitor or setup controls from a remote area using the internet or local IP network and any standard web browser. Functions and controls include: on\/off, pulse and monitor. LED indicator lights on the device provide the real-time information about digital input voltage, relay coil, network status and network activity. Password protection for the setup page is available (10 characters maximum). \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 34%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClick Photo to Enlarge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nWe now offer our second generation LED tube lamps with this fixture which have increased this hazardous location lightÃ¢â‚¬â„¢s performance. This two lamp HAZLOC LED linear fixture is lighter in weight and produces more light than hazardous location fluorescent fixtures. The four foot long LED tube design bulbs included with this unit are rated at 50,000 hours of service life, which isÃ‚Â over twice as long as standard T8 bulbs. \nThe HALP-ANC-48-2L-LED is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. This fixture also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This lamp offers the extreme durability, high efficiency and long lamp life of high power LEDs in a proven hazardous location fixture design, making it a reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present.\n \nWe have eliminated the ballast box normally associated with fluorescent fixtures which reduces overall weight and creates a slimmer unit profile. There is no ballast in this unit and the included  LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. \nUnlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the \"tube\" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. \nThe 28 watt LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. Each lamp produces 3,500 lumens at 125 lumens per watt, for a combined 7,000 total lumen light output. A HAL-48-2L-T8 hazardous location fluorescent light, with a combined total of 64 watts, draws 0.54 amps at 120 volts AC. This LED version of the same light, with a total of 56 watts, draws only 0.47 amps at 120 volts AC. The HAL-48-2L-LED-G2 is universal voltage, not multi-tap, and operates on any voltage from 120V to 277V AC 50\/60hz without any modifications. We also make a 12\/24V AC\/DC version for low voltage applications for AC or DC power. \nNetwork: The network controller is equipped with one optically-isolated digital input and one SPDT relay contact. Compatible with 9-28V DC, the unit features a 3-position removable relay (N, NO, NC), a 5-position removable power\/inputs and an 8-pin RJ-45 port for network connections. Operators can mount the device on walls, surfaces or din rails for space-saving benefits. \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eEnergy Consumption Comparison\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eT5HO\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eT8\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eWattage\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e108 watts\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e64 watts\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e56 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 120V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.90 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.54 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.47 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 220V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.49 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.29 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.25 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 240V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.45 amps\u003c\/td\u003e\n \u003ctd style=\"width: 117px; text-align: center;\"\u003e0.27 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.23 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 277V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.39 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.24 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.20 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 12V DC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e9Ã‚Â amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e5.34 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e4.67 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 24V DC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e4.5 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e2.67 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e2.34Ã‚Â amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eLamp Life Expectancy\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e20,000 hours\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e24,000 hours \u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eColor Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e5000KÃ‚Â \/ 4100K\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e4100K\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e5600K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eOperation cost per year\n(12hs\/day @ 12c\/kWh)\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$56.77\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$33.64\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$29.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nMounting Options: Unless otherwise specified, our standard, most popular configuration is the flange mount shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations. \n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Mount (Standard)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nStandard Flange Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 38.25Ã¢â‚¬Â on center apart along the top of this hazardous location light. The mounting holes are 7.2Ã¢â‚¬Â on center across the top of the light. \n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePendant Mount (Optional)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nStandard Suspension Mounting: Pendant mount fixtures hang from the ceiling and are suspended by rigid pipe. Each fixture is equipped with either two 1\/2\" or 3\/4Ã¢â‚¬Â NPT hubs, one on each end of the fixture. Operators bring rigid pipe down to the threaded mounting hubs. Wiring is fed down through the rigid pipe to one of the NPT hubs and tied in to the fixtureÃ¢â‚¬â„¢s lead wires, completing the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. \nSuggested Applications: The HALP-ANC-48-2L-LED is designed for Modbus TCP\/IP lighting networks, remote lighting networks, marine, wet, damp locations where corrosion resistant fluorescent lights are required or are already present. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent\/cleaning areas, water treatment areas, processing plants and marine loading docks.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38276191387829,"sku":"PL3-HALP-ANC-48-2L-LED","price":3200.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-HALP-ANC-48-2L-LED.jpg?v=1629081091","url":"https:\/\/getcahits.com\/products\/pl3-halp-anc-48-2l-led","provider":"PuriLite","version":"1.0","type":"link"}