{"product_id":"pl3-halp-48-2l-led-d","title":"Dimmable Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine Saltwater","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eHALP-48-2L-LED-D Hazardous Area LED Offshore Light\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eU.L. Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eListing: United States - Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I Division 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: W-8.25\" x L-52\" x H-7\"\u003c\/td\u003e\n\u003ctd\u003eClass II, Division 2, Groups F, G \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight:8 Lbs \u003c\/td\u003e\n\u003ctd\u003eUL 844 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Watts: 46 watts (23 Watts Per Lamp) \u003c\/td\u003e\n\u003ctd\u003eUL 1598A Marine Type (Salt water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lumens: 5,750 (2,875 Per Lamp)\u003c\/td\u003e\n\u003ctd\u003eCalifornia Title 24 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: Universal 90-132V AC, 220-240V AC, or 11-25V AC\/DC\u003c\/td\u003e\n\u003ctd\u003eT4A Temperature Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Life Expectancy: 50,000 Hours\u003c\/td\u003e\n\u003ctd\u003eDimmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminous Efficacy: 125 Lumens per Watt\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range: -30Ã‚Â°C to +85Ã‚Â°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Angle: 150Ã‚Â°\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Temp: 5600K or 4500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMinimum Operating Temp: -30 C\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMaximum Case Temp: 90 C\u003c\/td\u003e\n\u003ctd\u003eToll Free:Ã‚Â 1-800-369-6671\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting: Flange Type Surface Mount or Pendant Mount\u003c\/td\u003e\n\u003ctd\u003eIntl:Ã‚Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Hub: 1\/2\" or 3\/4\" threaded\u003c\/td\u003e\n\u003ctd\u003eFax:Ã‚Â 1-903-498-3364\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU.L Approval:Ã‚Â Ã‚Â Ã‚Â \u003c\/td\u003e\n\u003ctd\u003eE-mail:Ã‚Â \n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\nMade in the USA \nThe Larson Electronics HALP-48-2L-LED-D Hazardous Area Dimmable LED Light Fixture is U.S.\/Canada UL Listed Class 1 Division 2 Groups A, B, C and D, UL 1598A listed, and is specifically designed to handle the rigors of wet and corrosive marine environments. This hazardous location LED light has a T4 temperature rating and carries a United States Coast Guard approval, making it ideal for applications such as oil rigs, ships, offshore applications, petrochemical, manufacturing, chemical storage, and water treatment centers. \nThis four foot long, two lamp dimmable LED fixture is ideal for operators seeking a top quality hazardous location light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The HALP-48-2L-LED-D hazardous area LED light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Eight corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n \u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 34%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClick Photo to Enlarge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nWe now offer our second generation LED tube lamps with this fixture which have increased this hazardous location lightÃ¢â‚¬â„¢s performance. This dimming two lamp HAZLOC LED linear fixture is lighter in weight and produces more light than hazardous location fluorescent fixtures. The four foot long LED tube design bulbs included with this unit are rated at 50,000 hours of service life, which isÃ‚Â over twice as long as standard T8 bulbs. \nThe HALP-48-2L-LED-D is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. This fixture also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This lamp offers the extreme durability, high efficiency and long lamp life of high power LEDs in a proven hazardous location fixture design, making it a reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present.\n \nWe have eliminated the ballast box normally associated with explosion proof fluorescent fixtures which reduces overall weight and overall complexity of installation. There is no ballast in this unit and the included dimmable  LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. These fluorescent LED lamps have internal drivers, eliminating external power components. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. This second generation lamp is offered in 5600K cool white, 4500K natural white, and 3000K warm white. Our standard unit ships with 5600K unless different color temperature is specified. \nThese are the first generation of our dimmable 23 watt LED tubes. Lumen output is 125 lumens per watt for a total of 2,875 lumens per bulb. While fluorescent lamps are omni-directional and illuminate 360Ã‚Â°, the LED style replacement lamps are directional and offer a 160Ã‚Â° beam spread. This allows for directed illumination where it is needed and not wasting light via reflectors or or over illuminating areas. This dimming LED tube uses electronic silicon control dimming. We have tested these lamps on all Lutron and Leviton electronic dimmers, such as the Leviton 6633-PLW. When using electronic dimmer switches, fixtures equipped with the LEDT8-48-D LED bulb will dim from 0% up to 100% via the user provided dimming switch. Please note: the dimmer switch must be installed outside the hazardous environment or use an explosion proof dimmer switch. This fixture will is offered in three voltage ranges: 90-132V AC 50\/60Hz, 220-240V AC 50\/60Hz, and 11-25V AC\/DC. Operating the LED lamps outside of the designed voltage range may result in internal damage when higher voltage is applied to the lamps, and the lamp may not fuction on lower voltages.\nUnlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the \"tube\" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. \nUnlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the \"tube\" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. \nThe 28 watt LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. Each lamp produces 2,875 lumens at 125 lumens per watt, for a combined 5,750 total lumen light output. A HAL-48-2L-T8 hazardous location fluorescent light, with a combined total of 64 watts, draws 0.54 amps at 120 volts AC. This LED version of the same light, with a total of 56 watts, draws only 0.47 amps at 120 volts AC. The HAL-48-2L-LED-G2 is universal voltage, not multi-tap, and operates on any voltage from 120V to 277V AC 50\/60hz without any modifications. We also make a 12\/24V AC\/DC version for low voltage applications for AC or DC power. \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eEnergy Consumption Comparison\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eT5HO\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eT8\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eWattage\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e108 watts\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e64 watts\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e46 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 120V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.90 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.54 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.38 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 220V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.49 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.29 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.21 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 240V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.45 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.27 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.19 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 277V AC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.39 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.24 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e0.17 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 12V DC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e9Ã‚Â amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e5.34 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e3.83 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAmp Draw @ 24V DC\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e4.5 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e2.67 amps\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e1.92Ã‚Â amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eLamp Life Expectancy\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e20,000 hours\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e24,000 hours \u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eOperation cost per year\n(12hs\/day @ 12c\/kWh)\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$56.77\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$33.64\u003c\/td\u003e\n\u003ctd style=\"width: 117px; text-align: center;\"\u003e$24.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003ePlease note: operation costs are calculated with the light fixture at 100% illumination. When dimming the light fixture below 100%, electrical consumption will be lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nMounting Options:Ã‚Â Unless otherwise specified, our standard, most popular configuration is the flange mount shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations. \n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Mount (Standard)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nStandard Flange Brackets:Ã‚Â Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 38.25Ã¢â‚¬Â on center apart along the top of this hazardous location light. The mounting holes are 7.2Ã¢â‚¬Â on center across the top of the light. \n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePendant Mount (Optional)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nStandard Suspension Mounting:Ã‚Â Pendant mount fixtures hang from the ceiling and are suspended by rigid pipe. Each fixture is equipped with either two 1\/2\" or 3\/4Ã¢â‚¬Â NPT hubs, one on each end of the fixture. Operators bring rigid pipe down to the threaded mounting hubs. Wiring is fed down through the rigid pipe to one of the NPT hubs and tied in to the fixtureÃ¢â‚¬â„¢s lead wires, completing the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. \nSuggested Applications: The HALP-48-2L-LED-D is designed for marine, wet, damp locations where corrosion resistant fluorescent lights are required or are already present. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent\/cleaning areas, water treatment areas, processing plants and marine loading docks.\n\n\u003ctable cellpadding=\"2\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 28px;\"\u003eMade in USA Quality\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003eSuperior LED Benefits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n1. Each unit dialectically tested.\n2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface.\n3. Fixture housing constructed of glass fiber reinforced polyester.\n4. No ballast box. No ballast to replace. We simply run the black wire to one end of the bulb and white wire to the other.\n5. Re-lamping done via 6 stainless steel snap locking latches which enables the operator to remove the door and access the lamps.\n6. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection.\n7. 1\/2\" or 3\/4\", threaded access hole for wiring conduit.\n8. Dimmable LED lamps\nÃ‚Â \nÃ‚Â \n\u003c\/td\u003e\n\u003ctd\u003e1. 50,000 hour lifespan.\n2. Can SAVE 50% or more on energy.\n3. Qualifies retrofit projects for financial incentives, including utility rebates, tax credits and energy loan programs.\n4. Reduces energy use and prolongs life-spans of peripheral cooling units (A\/C, refrigeration)\n5. 100% recyclable.\n6. No toxins-lead, mercury.\n7. No UV light, infrared radiation or CO2 emissions.\n8. Qualifies buildings for LEED and other sustainable business certifications.\n9. Bright, even light maintains consistent color over time.\n10. Instant on\/off Ã¢â‚¬â€œ No flickering, delays or buzzing.\n11. Very good color rendering.\n12. Vibration\/impact resistant.\n13. Significantly cooler operation.\n14. Less frequent outages, higher output improves workplace safety. \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38276204036277,"sku":"PL3-HALP-48-2L-LED-D","price":1742.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-HALP-48-2L-LED-D.jpg?v=1629080897","url":"https:\/\/getcahits.com\/products\/pl3-halp-48-2l-led-d","provider":"PuriLite","version":"1.0","type":"link"}