{"product_id":"pl3-exp-emg-ext-le6-1l-v2","title":"Explosion Proof Exit Sign - Class I, Division 1 \u0026 2 - IP65 - 120V\/277VAC - Emergency Battery Back-Up","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEXP-EMG-EXT-LE6-1L-V2 Explosion Proof Exit Sign\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\/Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eListing: United States \u0026amp; Canada\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eListed for United States \u0026amp; Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Type: LED\u003c\/td\u003e\n\u003ctd\u003eClass I, Divisions 1 \u0026amp; 2, Groups B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 25â‚¬ÂH x 13â‚¬ÂW x 10.5â‚¬ÂD\u003c\/td\u003e\n\u003ctd\u003eClass I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage:120\/277VAC\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2, Groups E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts: 1.1\u003c\/td\u003e\n\u003ctd\u003eClass III, Divisions 1 \u0026amp; 2\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLighting Configuration: Back Illuminated Sign Panel\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, 4, 7 (B, C, D), 9 (E, F, G)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup Runtime: 3 Hours\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 508A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup: Nickel Cadmium Battery Pack\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 1203\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eAmbient Operating Temp: 0Â°F to +113Â°F\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to CSA C22.2 No 14, 25, 30 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMaterials: Copper Free Aluminum Housing\u003c\/td\u003e\n\u003ctd\u003e3 Hour Emergency Runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMounting:Â  Ceiling Mount, Pendant Mount, Wall Mount\u003c\/td\u003e\n\u003ctd\u003eSelf-Testing Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eWiring: 3\/4\" NPT Wiring Hub\u003c\/td\u003e\n\u003ctd\u003eRight or Left Arrow Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003e\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003ctd\u003eToll Free:Â 1-800-369-6671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003ctd\u003eIntl:Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nMade in the USA\nThe EXP-EMG-EXT-LE6-1L-V2 Explosion Proof LED Exit Sign with emergency battery back up from Larson Electronics is Class I, Divisions 1 \u0026amp; 2, Groups B, C, D, Class I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA, Class II, Divisions 1 \u0026amp; 2, Groups E, F, G and Class III Divisions 1 \u0026amp; 2 rated for hazardous areas. Equipped with a 1.1 watt LED lamp, a 3 hour runtime and self diagnostic system, this failsafe exit sign helps show workers within hazardous environments where the exit is during power failures. This single sided exit sign is an ideal emergency exit marking solution for hazardous locations where failsafe reliability is a must, and features arrows to indicate the direction of the nearest exit - right and left options are available.\nThe EXP-EMG-EXT-LE6-1L-V2 is an effective option for operators who wish to ensure their hazardous workspaces employ the most up to date and reliable means of marking emergency exit-ways, with either right or left arrows to indicate the direction of the nearest exit. TheÂ exit sign can be displayed withoutÂ arrows whenÂ not signifying a direction.Â  Under normal conditions this emergency exit lamp uses normal external power to illuminate its 1 watt LED array. In the case of power outages or in any situation where power is interrupted, this unit automatically switches to a battery backup which will power the unit for three hours or until power is restored. This fixture has three mounting options and is multi-voltage capable.\nLight Features: The EXP-EMG-EXT-LE6-1L-V2 features a backlit LED array that each contain eight LEDs, drawing a total of 1.1 watts. This explosion proof emergency LED fixture features brown-out, short circuit and voltage surge protection and has a low voltage disconnect which prevents damage to the battery caused by a deep discharge. This self-testing LED fixture will run for a minimum of 3 hours after a power failure thanks to the maintenance-free 3.6 volt NiCad battery. After emergency use, the battery takes 24 hours to completely recharge.\n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClick Photo to Enlarge \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\nThis emergency exit marking fixture is explosion proof and carries an integral battery backup power supply. When external power is cut due to outages or accidents this lamp automatically switches to its battery backup which will power the lamp for three hours, longer than the requirements specified in the NFPA 101. The EXP-EMG-EXT-LE6-1L-V2 sign panel is back illuminated by LEDs and as a result draws only 1.1 watt of power and has an extreme LED luminary lifespan rated at 15 years. This fixture is approved for outdoor use and is resistant to saltwater making it suitable for use in marine environments.\nEmergency Operation: The EXP-EMG-EXT-LE6-1L-V2 features a backup battery that will run the fixture for at least 90 minutes following a power outage or any other loss of power. The included emergency backup battery is a 3.6 volt NiCad rechargeable unit. These batteries are maintenance-free and have a life expectancy of 15 years while being able to operate in a wide variety of conditions including in temperatures ranging from 0Â°F to +113Â°F. This unit also features a low voltage disconnect. This means that if the fixture detects that the battery`s terminal voltage has fallen below a certain level, the low voltage circuit will disconnect the emergency lighting load until normal power is restored. This prevents the battery from experiencing a deep discharge and becoming damaged.\nWiring: The EXP-EMG-EXT-LE6-1L-V2 explosion proof emergency self-testing LED fixture is NOT a factory sealed fixture. Operators will bring their own wiring to a junction box and complete their connects. The operator will also provide their own seal off for this fixture. The EXP-EMG-EXT-LE6-1L-V2 operates on 120\/277V ACÂ at 60Hz.\nMounting: The EXP-EMG-EXT-LE6-1L-V2 is designed to be surface mounted to flat surfaces such as walls. The unions connecting the upper lamps to the lower indicator light enclosure allow for both horizontal and vertical adjustment. This gives operators the ability to adjust the light to their specific mounting location for ideal light coverage during a power failure or power outage.\nSuggested Applications: The EXP-EMG-EXT-LE6-1L-V2 is designed to for use within hazardous environments to mark the exit-ways of rooms and buildings.\n\n\u003ctable cellpadding=\"2\" width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 28px;\"\u003eMade in the USA Quality\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003eSuperior LED Benefits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n1. Uniform LED illumination\n2. Battery Replacement Notification Built In\n3. Universal 120V\/277V AC Selectable\n4. 3 Hour Battery Backup Runtime\n5. Copper-free aluminum housing\n6. 3\/4â‚¬Â NPT conduit hubs\n7. Maintenance free\n8. 15 Year LED Rated Lifespan\n9. Fully Automatic Operation\n10. Self Testing System\n11. High Intensity LEDs\n12. Low Power Consumption (1.1 watts)\n13. Fully Electronic Circuit Control \n\u003c\/td\u003e\n\u003ctd\u003e\n1. Extreme long life.\n2. High efficiency and low amp draw.\n3. High durability and reliability.\n4. Small size and light weight.\n5. 100% recyclable.\n6. No toxins-lead, mercury.\n7. High light output.\n8. Consistent color over time.\n9. High Versatility.\n10. No fragile glass used in construction. \n12. Vibration\/impact resistant.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38264270487733,"sku":"PL3-EXP-EMG-EXT-LE6-1L-V2","price":3806.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EXP-EMG-EXT-LE6-1L-V2.jpg?v=1628472357","url":"https:\/\/getcahits.com\/products\/pl3-exp-emg-ext-le6-1l-v2","provider":"PuriLite","version":"1.0","type":"link"}