{"product_id":"pl3-exp-emg-2l-le6-v8","title":"Explosion Proof Bug Eye Emergency LED Fixture - Class I, II, III - (2) LED Lamps - Power Relay","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 56%;\"\u003eEXP-EMG-2L-LE6-V8 Explosion Proof Emergency LED Exit Sign\u003c\/td\u003e\n\u003ctd style=\"width: 44%;\"\u003eRatings\/Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing: NRTL Listed for United States and Canada\u003c\/td\u003e\n\u003ctd style=\"width: 44%;\"\u003eClass I, Divisions 1 \u0026amp; 2, Groups B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Technology: LED\u003c\/td\u003e\n\u003ctd\u003eClass I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 25â‚¬ÂH x 22â‚¬ÂW x 4.5â‚¬ÂD\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2, Groups E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: -\u003c\/td\u003e\n\u003ctd\u003eClass III, Divisions 1 \u0026amp; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage: 120\/277V AC, 60Hz\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, 4, 7 (B,C,D), 9 (E,F,G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts: 2.2W\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 508A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens: 66 lms\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 1203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuminous Efficacy: 30 Lm\/W\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to CSA C22.2 No 14, 25, 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Life Expectancy: 100,000 Hours\u003c\/td\u003e\n\u003ctd\u003eHorizontal and Vertical Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Light Color: White\u003c\/td\u003e\n\u003ctd\u003eCE Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRI: -\u003c\/td\u003e\n\u003ctd\u003ePower Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Type: -\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Base: -\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Lamp: -\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBeam Angle: -\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eLighting Configuration: Flood Pattern\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustability: Lamp Heads Horizontally \u0026amp; Vertically Adjustable\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps: 0.018A @ 120V, 0.009A @ 240V, 0.007A @ 277V\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eAmbient Operating Temp: 0Â°F to +113Â°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material: Die Cast Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Color: Powder Coated - Grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLens Material: Polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting: Surface Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring: Operator Provided Wiring \u0026amp; Seal Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe EXP-EMG-2L-LE6-V8 from Larson Electronics is an Explosion Proof Bug Eye Emergency LED Fixture that is Class I, Divisions 1 \u0026amp; 2, Groups B, C, D, Class I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA, Class II, Divisions 1 \u0026amp; 2, Groups E, F, G and Class III, Divisions 1 \u0026amp; 2 rated for hazardous areas. The EXP-EMG-2L-LE6-V8 produces 66 total fixture lumens while drawing only 2.2 total watts and and features a power relay, which connects with existing power systems and backup power systems (emergency power source not included). \nThe EXP-EMG-2L-LE6-V8 explosion proof emergency bug eye LED fixture is ideal for installation in hazardous areas that require emergency illumination in the event of a power failure or power outage. This fixture features three explosion proof enclosures that are configured in a bug eye layout. The two upper enclosures house the LEDs while the bottom enclosure contains an indicator light. The unions between the upper enclosures and the lower enclosure allow for both horizontal and vertical adjustment. \nLight Features: The EXP-EMG-2L-LE6-V8 features two lamps that each contain eight LEDs that draw a total of 1.1 watts per lamp. Each lamp produces 33 lumens of high-intensity white LED light for a fixture total of 66 lumens produced while drawing a total of 2.2 watts. This explosion proof emergency LED fixture features brown-out, short circuit and voltage surge protection. \nLED Benefits: Unlike gas burning and arc type lamps that have glass bulbs, LEDs have no filaments or fragile housings to break during operation and\/or transportation. Instead of heating a small filament or using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current is applied, providing instant illumination with no warm up or cool down time before re-striking. Because there is no warm up period, this light can be cycled on and off with no reduction in lamp life.\nLED lights run at significantly cooler temperatures than traditional metal halide and high pressure sodium lights and contain no harmful gases, vapors, or mercury, making them both safer and more energy efficient. No extra energy is wasted in cooling enclosed work areas due to external heat emissions from bulb type lights, and the operator risks associated with traditional lighting methods, such as accidental burns and exposure to hazardous substances contained in the glass bulbs, are eliminated. In addition, LEDs are also safer for the environment as they are 100% recyclable, which eliminates the need for costly special disposal services required with traditional gas burning and arc type lamps. \nExplosion Proof Ratings: The EXP-EMG-2L-LE6-V8 from Larson Electronics is an explosion proof emergency LED fixture. This particular unit is Class I, Divisions 1 \u0026amp; 2, Groups B, C, D, Class I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA, Class II, Divisions 1 \u0026amp; 2, Groups E, F, G and Class III, Divisions 1 \u0026amp; 2 rated for hazardous areas.\nWiring: The EXP-EMG-2L-LE6-V8 explosion proof emergency LED fixture is NOT a factory sealed fixture. Operators will bring their own wiring to a junction box and complete their connects. The operator will also provide their own seal off for this fixture. The EXP-EMG-2L-LE6-V8 operates on 120\/277V AC @ 60Hz and contains a power relay that activates the light. This unit can be wired to existing power systems and backup power systems. When power is unavailable, the LED fixture detects the disconnection and activates the light. The emergency circuit powers the light in such instances.\nMounting: The EXP-EMG-2L-LE6-V8 is designed to be surface mounted to flat surfaces such as walls. The unions connecting the upper lamps to the lower indicator light enclosure allow for both horizontal and vertical adjustment. This gives operators the ability to adjust the light to their specific mounting location for ideal light coverage during a power failure or power outage.\nSuggested Applications: The EXP-EMG-2L-LE6-V8 is ideal for use as emergency lighting in areas where an explosion proof fixture is required.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38267556528309,"sku":"PL3-EXP-EMG-2L-LE6-V8","price":3338.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EXP-EMG-2L-LE6-V8.jpg?v=1628565999","url":"https:\/\/getcahits.com\/products\/pl3-exp-emg-2l-le6-v8","provider":"PuriLite","version":"1.0","type":"link"}