{"product_id":"pl3-exp-ms-n4x-at-hv","title":"400W Explosion Proof Motion Sensor - 20' to 25' Mounting Height - 15' x 15' Area Coverage - Timer","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEXP-MS-N4X-AT-HV Explosion Proof Adjustable Motion Sensor \u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings \/ Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing: NRTL Listed for United States, Canada and IECEx\/ATEX Rated\u003c\/td\u003e\n\u003ctd\u003eListed for United States \u0026amp; Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eDimensions: 7\"-W x 5\"-H x 9\"-D\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I, Divisions 1 \u0026amp; 2, Groups B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection: Motion\u003c\/td\u003e\n\u003ctd\u003eClass I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Coverage: 15` x 15` (Mounted @ 20-'25')\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2, Groups E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTilt Angles: -90Â° to +30Â° - Elevation\u003c\/td\u003e\n\u003ctd\u003eClass III, Divisions 1 \u0026amp; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReach: 6.5` to 32` - Adjustable\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, 4, 7 (B, C, D), 9 (E, F, G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Voltage: 120V, 208V, 220V, 240V or 277V AC\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 508A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wattage: 400W\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 1203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Hold Time: 0.5 Secs to 15 Mins (Adjustable)\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to CSA C22.2 No 14, 25, 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Frequency: 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range: -22Â°F to +140Â°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated Frequency: 5.8 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation: Normally Opened or Normally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring: Flying Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EXP-MS-N4X-AT-HV Explosion Proof Motion Sensor is approved for Class I, Divisions 1 \u0026amp; 2 and Class II, Divisions 1 \u0026amp; 2 rated areas and provides the ability to power lights or other equipment within hazardous locations based on motion. This C1D1 rated motion sensor features adjustable sensitivity and time delay after motion. Designed for mounting at a height ranging between 20-25 feet, the EXP-MS-N4X-AT-HV can handle a maximum load of 400 watts.\nThis explosion proof motion sensor is ideal for operators seeking a high quality explosion proof motion sensor rated for use in hazardous areas designated Class I, Divisions 1 and Class II, Division 1. This explosion proof motion detector provides up to 15` by 15` coverage when mounted at 20'-25'. The entire unit is constructed of copper free non-sparking aluminum construction with a glass window for motion detection. This unit is easily wall mounted via integral mounting bracket, which can be adjusted -90Â° to +30Â° vertically after installation. The explosion proof housing provides two 1\/2\" or 3\/4\" hub openings located on either side of the housing for running electrical conductors in a feed through configuration. A bushing seal at each conductor opening prevents damage to wiring insulation. \nThis unit leverages cutting-edge microwave sensors to detect motion. When in use, the device sends out discreet waves that are reflected back from nearby walls and objects (not heat or light). Microwave sensors are not affected by line of sight, resulting in wider and more accurate coverage of the target area. By comparison, traditional infrared sensors can only detect heat and light (factors used to identify movement) within the unitâ‚¬â„¢s field of view. Microwave sensors also provide stable performance in unpredictable climates and can penetrate glass, plastic and other non-metallic objects. \n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eEXP-MS-N4X-AT in operation.  to view our Flex Couplers available for purchase. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eClick Images to Enlarge \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nReach Setting: For best results, it is recommended to adjust the motion sensitivity of the unit by configuring the reach setting. Reach is the term used to describe the radius of the circular detection zone produced on the ground. After mounting the sensor at a height of 20-25 feet, operators can adjust each control to select distance sensitivity. This detection distance is measured using a person who is between 5.2 feet and 5.5 feet tall with an average build, moving at a speed of 1.0-1.5m\/sec. If any of these variables are changed, the detection distance will also change. \nThe EXP-MS-N4X-AT-HV operates like a standard on\/off light switch. The circuit is normally open when no motion is present. Once motion is detected, the internal switch changes to a closed circuit, allowing voltage to pass through the sensor and power the device(s) at the other end.\nThis unit is designed to operate on 120V, 208V, 220V, 240V or 277V AC electrical circuits. We also offer low voltage 12-24V AC or DC electrical systems. This motion sensor is suitable for use in environments where combustible dusts and particulates may be present.\n\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Detected Through a Wall \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\nThe EXP-MS-N4X-AT-HV has 1\/2\" or 3\/4\" NPT tapped conduit openings on either of the unit in feed through versions while dead end versions have a single conduit hub, providing easy and secure connection to main power line supplies. \nSuggested Applications: Manufacturing, Industrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where Combustible Dust is Present.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38363950186677,"sku":"PL3-EXP-MS-N4X-AT-HV","price":5156.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EXP-MS-N4X-AT-HV.jpg?v=1628473227","url":"https:\/\/getcahits.com\/fr\/products\/pl3-exp-ms-n4x-at-hv","provider":"PuriLite","version":"1.0","type":"link"}