{"product_id":"pl3-exp-akc-dns-12v","title":"Explosion Proof Sensor Security Terminal - 12V DC - (2) Inputs, (2) Outputs - KNX System","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 56%;\"\u003eEXP-AKC-DNS-12V Explosion Proof Security Terminal\u003c\/td\u003e\n\u003ctd style=\"width: 44%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 56%;\"\u003eListing: NRTL Listed for United States and Canada\u003c\/td\u003e\n\u003ctd style=\"width: 44%;\"\u003eListed for United States \u0026amp; Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 4 1\/4\" x 2 5\/8\"\u003c\/td\u003e\n\u003ctd\u003eClass I, Divisions 1 \u0026amp; 2, Groups B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 1 lb\u003c\/td\u003e\n\u003ctd\u003eClass I, Zones 1 \u0026amp; 2, Groups IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAux Voltage: 12V DC + 1.6V SELV\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2, Groups E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAux Current: 13mA to 43 mA\u003c\/td\u003e\n\u003ctd\u003eClass III, Divisions 1 \u0026amp; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption KNX: \u0026lt; 6 mA \u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, 4, 7 (B, C, D), 9 (E, F, G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs: (2)\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 508A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs: (2) Monostable Relay\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to UL 1203\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: Feraloy Iron Alloy\u003c\/td\u003e\n\u003ctd\u003eNRTL Listed to CSA C22.2 No 14, 25, 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections: Bus Connection Terminal (KNX - Black\/Red), Screw Terminals (Aux Voltage, Inputs and Outputs)\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: Surface\/Conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHubs: (2) 3\/4\" Feed-Thru Hubs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eToll Free:Â 1-800-369-6671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EXP-AKC-DNS-12V Explosion Proof Security Terminal is recommended for effective sensor communication, monitoring and signaling in Class I, II and III rated work sites. The low voltage interface works with KNX systems and comes equipped with two inputs and two outputs. This unit can be used to support remote lighting systems, security systems, hallway lighting and perimeter lighting systems. \nThe EXP-AKC-DNS-12V facilitates seamless integration between customer-provided equipment, such as security sensors, and KNX systems. This unit operates on 12V DC and features two monitored inputs, as well as two monostable relay outputs. The explosion proof interface is suitable for sending output signals to upstream systems. This unit contains bus terminals (black\/red) for connection with KNX components. Screw terminals are provided for connecting auxiliary voltage, inputs and outputs. For durability, the EXP-AKC-DNS-12V is protected by a feraloy iron alloy housing.\nHubs: The explosion proof device contains two, 3\/4\" feed-thru hubs. \nMount: The EXP-AKC-DNS-12V is compatible with surface or conduit mounting applications.\nApplications: Automation, security, integration with KNX systems, HID, incandescent and fluorescent luminaries\/lighting systems in hazardous locations, such as oil and gas facilities, chemical processing plants, food manufacturing establishments, mining sites and more. \n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40711766802613,"sku":"PL3-EXP-AKC-DNS-12V","price":2054.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EXP-AKC-DNS-12V.jpg?v=1628472604","url":"https:\/\/getcahits.com\/fr\/products\/pl3-exp-akc-dns-12v","provider":"PuriLite","version":"1.0","type":"link"}