{"product_id":"pl3-eppo-icb-230v-2w3p-16a","title":"Explosion Proof Power Plug and Receptacle - Class I, II, III - 16A, 230V - Circuit Breaker Switch - T6 Temp Rating","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEPPO-ICB-230V-2W3P-16A Explosion Proof Receptacle and Plug\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle Specs:\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I, Divisions 1 \u0026amp; 2 Groups C \u0026amp; D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing: NRTL Listed for United States, Canada\u003c\/td\u003e\n\u003ctd\u003eClass 1, Zones 1 \u0026amp; 2 IIB+H2, IIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eDimensions:Â 10 1\/2\" x 9 3\/4\" x 5 3\/4\"\u003c\/td\u003e\n\u003ctd\u003eClass II, Divisions 1 \u0026amp; 2 Group F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: -\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eVoltage Rating: 230 V\u003c\/td\u003e\n\u003ctd\u003eNEMA 3, 4, 4X 7(B,C,D), 9(F,G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating:Â 16 Amps\u003c\/td\u003e\n\u003ctd\u003eT6 Temperature Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP:  5 HP @ 240 V 1 PH\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: 2-Wire, 3-Pole\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection: On\/Off Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAux Contact: Late-make Early-break, Rated @ 10 A, 1\/3 HP 125\/250 V AC\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: Copper Free Aluminum \u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Electrostatically Applied Polyester\/Epoxy \u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: Wall\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring: Regular Stranding #10 Maximum\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Configuration: Feed Thru or Dead End\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Size: 1\" NPT\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rating: T6\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Specs:\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing: NRTL Listed for United States, Canada\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eDimensions: 6 11\/16\" x 3\"\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: -\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eVoltage Rating: 230V \u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating:Â 16 Amps\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP: 5HP @ 240V 1PH\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: 2-Wire, 3-Pole\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: Copper Free Aluminum \u003c\/td\u003e\n\u003ctd\u003eSpecial Orders - Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Electrostatically Applied Polyester\/Epoxy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: -\u003c\/td\u003e\n\u003ctd\u003eToll Free:Â 1-800-369-6671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring: Regular Stranding #10 Maximum\u003c\/td\u003e\n\u003ctd\u003eIntl:Â 1-214-616-6180\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Configuration: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub Size: 1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EPPO-ICB-230V-2W3P-16AÂ Explosion Proof Receptacle and Plug is approved for Class I, Divisions 1 \u0026amp; 2, Class II, Divisions 1 \u0026amp; 2 and Class III sites and provides a safe and secure power connection for portable or stationary electrical devices and equipment in hazardous locations. This 2-wire, 3-pole unit is constructed of copper-free aluminum and operates with 230 V AC. Rated atÂ 16 amps, both devices can be used in Class I rated locations.\nThe explosion proof power receptacle and plug is designed for use in combustible work sites, including Class I. This 16-amp receptacle features compatibility with 230 V AC. This 2-wire, 3-pole unit is constructed of copper-free aluminum with an electrostatically applied polyester\/epoxy finish and contains an integral circuit breaker which provides short circuit and thermal overload protection as well as manually operable protection during connection and disconnection of electrical cables. This unit is easily wall mounted via two screw slot tabs at the side of the housing and contains a feed-thru or dead-end configuration with 1\" NPT hub size.\nThe explosion proof plug takes on an octagon-style design. Insulators have high\nmechanical and dielectric strength and are low arc tracking. The device takes on a NEMA 4X rating when used with a compatible receptacle and a tightened locking ring. This plug is suitable for Type P marine cable.\nIntegral circuit protection: This unit contains a circuit breaker to allow safe,16 Amp at 230 V AC max operation. The circuit breaker also gives protection against short circuits and provides added thermal time delay overload protection. The plug and receptacle contacts cannot be made or broken under load. When the plug is inserted, the plug and receptacle contacts engage before the switch closes. When the plug is withdrawn, the switch opens before the plug and receptacle contacts disengage. This provides the maximum safety of a dead front receptacle. Arcing is isolated in a flame and dust-tight chamber. No special interlock device or manual switch, operators simply pull the plug straight out.\nInterchangeability: The receptacle and plug are fully interchangeable with configured and certified to UL1686 devices, such as Crouse-HindsÂ® ArktiteÂ® or AppletonÂ® PowertiteÂ®. Standard location receptacle bolt hole patterns match competitive back boxes so users can perform upgrades without changing back boxes in instances where changing the conduit system is difficult.\nSuggested Applications: Manufacturing, Industrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where Combustible Dust is Present.\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40711823392949,"sku":"PL3-EPPO-ICB-230V-2W3P-16A","price":3812.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPPO-ICB-230V-2W3P-16A.jpg?v=1628473641","url":"https:\/\/getcahits.com\/fr\/products\/pl3-eppo-icb-230v-2w3p-16a","provider":"PuriLite","version":"1.0","type":"link"}