{"product_id":"pl3-eph-fh-wm-t3b-3kw-240v-1p","title":"3000W Explosion Proof Heater - Forced Fan Heater - C1D1, C2D1 - 240V 1PH - 580 CFM - Wall Mount","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eEPH-FH-WM-T3B-3KW-240V.1P Hazardous Location Fan\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eRatings\/Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eUnit Type: Hazardous Location Forced Fan Type Heater\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eClass I, Div 1 \u0026amp; 2 Groups C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 22.5\" x 17.75\" x 21\" (Fan w\/o Wall Mount)\u003c\/td\u003e\n\u003ctd\u003eClass II, Div 1 \u0026amp; 2 Groups E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 194 lbs\u003c\/td\u003e\n\u003ctd\u003e6,000 Cycles of Service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage: 240V AC\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage: 24V\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase: 1PH\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts: 3,000W\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTUs: 10,250\u003c\/td\u003e\n\u003ctd\u003eÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps: 14.8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFM: 580\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Throw: 24`\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rating\/Rise: T3A\/16.5Â°F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: Aluminum, Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Powder Coated Epoxy Paint Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount: Wall Mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Mounting Height: 8`\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor: Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"550\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px;\"\u003e\nThe Larson Electronics EPH-FH-WM-T3B-3KW-240V.1PÂ Hazardous Location Fan provides active heating in hazardous locations and cold-temperature work sites. This 3,000-watt forced fan heater is compatible with 240V single phase and features an airflow rate of 580 CFM (24` air throw). Operators can mount the hazardous location fan on walls or structures. \nThe EPH-FH-WM-T3B-3KW-240V.1PÂ is suitable for maintaining adequate temperatures in Class I, Divisions 1 \u0026amp; 2 and Class II, Divisions 1 \u0026amp; 2 work sites. This 3,000-watt fan forced heater operates on 240V single phase with 24V control voltage. The 14.8-amp rated unit supports an airflow rate of 580 CFM, capable of throwing air as far as 24 feet. This T3A temperature-rated fan features guard shields to protect internal, moving parts. \nThis hazardous location fan forced heater is constructed of 14 gauge steel and aluminum with stainless steel\/aluminum pressure relief valves. The unit is rated for 6,000 cycles of service. Versatile louvers allow operators to control the direction of air leaving the fan in real-time. For protection from freeze damage (up to -45Â° C), the unit utilizes a Ethylene Glycol to water mixture as a heat transfer fluid inside the heater core. \nMounting: The EPH-FH-WM-T3B-3KW-240V.1PÂ is designed for wall mount configurations. The mounting component measures 7\" x 25\" x 6.5\" and weighs 27 lbs. To mount the unit, operators must secure the fan to the wall using the attachment assembly. The mounting arm component connects the attachment assembly to the wall bracket, which is secured to the base wall or structure. Alternatively, the mounting arm can be directly bolted onto a base wall or structure that is made out of steel (without a wall bracket). The recommended mounting height for this hazardous location unit is 8 feet. \nApplications: Heating, manufacturing plants, chemical processing, cold-temperature facilities, farming operations, agricultural sites, flour processing, grain silos and more.\n\nÂ \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":40718121828533,"sku":"PL3-EPH-FH-WM-T3B-3KW-240V.1P","price":22960.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-EPH-FH-WM-T3B-3KW-240V.1P.jpg?v=1628565972","url":"https:\/\/getcahits.com\/fr\/products\/pl3-eph-fh-wm-t3b-3kw-240v-1p","provider":"PuriLite","version":"1.0","type":"link"}