{"product_id":"pl3-mt-pps-120-240v-1-5kw-40vdc-nw-r1","title":"1.5 kW Programmable DC Power Supply - 85 -265V AC Input - 0-40V DC Output - LXI TCP\/IP Ethernet","description":"\u003cdiv class=\"container-fluid\" id=\"ProductPageSpecContainer\"\u003e\n\u003cdiv class=\"container-fluid\" id=\"ProductPageProductSpecHeader\"\u003e\u003cb\u003eSpecifications \/ Additional Information\u003c\/b\u003e\u003c\/div\u003e \n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n \u003ctd style=\"width: 61%;\"\u003eMT-PPS-120.240V-1.5KW-40VDC-NW-R1 Industrial DC Power Supply\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eSummary\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ctable width=\"100%\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width: 61%;\"\u003eDevice Type: Programmable DC Power Supply\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003eSide Air Intake\/Rear Air Exhaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range: 85-265V AC (120-240V), 1PH\u003c\/td\u003e\n\u003ctd\u003e+LXI Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range: 50-400 Hz\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput DC Voltage: 0-40V DC (0-37ADC)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power: 1.5 kW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple: 40 mVrms\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation (Voltage Mode): Ã‚Â± 0.004% of Full Scale\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation (Current Mode): Ã‚Â± 0.02% of Full Scale\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation (Voltage Mode): Ã‚Â± 0.01% of Full Scale\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation (Current Mode): Ã‚Â± 0.04% of Full Scale\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eIsolation: Maximum Input Voltage to Ground Ã‚Â±2500V AC; Maximum Output Voltage to Ground Ã‚Â±1000V DC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eMaximum Slew Rate: 100 ms for Output Voltage\/Current Change from 0 to 63%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 14px;\"\u003eBandwidth: 3 Hz for Remote Analog Voltage Programming, 2 Hz for Remote Analog Current Programming\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor: 0.99 \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency: 86%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface: LXI TCP\/IP Ethernet Interface (+LXI)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Accuracy: Ã‚Â± 0.075% of Full Scale Voltage (Voltage Programming), Ã‚Â± 0.075% of Full Scale Voltage (OVT Programming), Ã‚Â± 0.075% of Full Scale Current (Current Programming), Ã‚Â± 0.075% of Full Scale Current (OCT Programming), Ã‚Â± 0.2% of Full Scale Voltage (Voltage Readback), Ã‚Â± 0.2% of Full Scale Current (Current Readback)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Analog Programming and Monitoring Levels: 0-10V DC\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Analog Output Impedances: 100ÃŽÂ© (Voltage\/Current Output Monitoring)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Digital Programming and Monitoring Limits: 0 to 5V DC\/10k Input Impedance (Input); 0 to 5V DC, 5 mA Drive Capacity (Output)\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Sense Limits: 3% Maximum Voltage Drop from Output to Load\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication: Front Panel, 37-pin Isolated Analog-digital User I\/O, RS232 Computer Interface\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\/Protection: AC Phase Loss, Excessive Thermal Conditions, Over Voltage Trip, Over Current Trip, Cleared Fuse, Excessive Program Line Voltage, Interlock Fault\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temp: 0Ã‚Â°C to +50Ã‚Â°C\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity: Up to 95% Non-condensing RH\u003c\/td\u003e\n\u003ctd\u003eÃ‚Â \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting: Front Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput AC Connection: 38660 Molex Input Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput DC Connection: 0.25Ã¢â‚¬Â x 0.75Ã¢â‚¬Â Tin Plated Copper Bus; (2) 3\/8-16 Threaded Insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions: 1.75\" x 19\" x 24\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e '\n\u003cb\u003eProduct Overview\u003c\/b\u003e\n' \u003cdiv class=\"product-description-wrap\" itemprop=\"description\"\u003e\n\u003ctable width=\"585\" border=\"0\"\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"height: 110px; width: 579px;\"\u003e\nThe MT-PPS-120.240V-1.5KW-40VDC-NW-R1 from Larson Electronics is a Programmable DC Power Supply for industrial sites and systems. This 1.5 kW unit is designed to convert single-phase input voltages ranging between 85-265V AC to low voltage 0-40V DC. This device may be installed on front panels and comes with several diagnostic and protective features. The unit is suitable for use in marine-related installations, electro-mechanical applications, semi-conductor fabrication equipment and factory automation.\nFeatures: This programmable DC output power supply supports a single-phase input range of 85-265V AC (120-240V AC). Output is provided within a low voltage range of 0-40V DC (0-37ADC) and maximum 1.5kW. Equipped with a stepless rotary knob for setting voltage\/current, the device features power and standby modes. Function keys on the panel includes: menu, item, V\/I DIS, TRIP DIS, CLEAR and ENTER. Meters display output voltage, output current, voltage set point, current set point, over voltage trip and over current trip. Operators may view various enabled\/disabled configurations on the front panel. \nThe industrial power supply features front panel, RS-232 computer interface and isolated 37-pin I\/O communication. This device features an efficiency rate of 86 percent and offers the following diagnostic\/protective functions: AC phase loss, excessive thermal conditions, over voltage trip (programmable), over current trip (programmable), cleared fuse, excessive program line voltage and interlock fault. It supports cooling by side air intake and rear air exhaust. \nInterface\/Connections: This DC power supply features LXI TCP\/IP Ethernet interface (+LXI). A 38660 molex input connector can be used for input connections. Output is facilitated by two 3\/8-16 threaded insert ports. \nMount: The MT-PPS-120.240V-1.5KW-40VDC-NW-R1 is suitable for front-panel mounting requirements, via four openings at every corner of the unit.\nNOTE: In order to obtain the best performance and the longest operational life from these units, it is recommended that you do not exceed 75% of the unit's output amperage. To determine if this converter suits your desired application, add together the total wattage of the equipment you intend to use with this unit and divide this total by 12 volts to find the total amperage draw that will be placed upon the converter. For example, if you are using two of our LEDP10W-120E 120 watt LED lights, 120 watts divided by 12 volts is 10 amps. This would mean the MT-PPS-120.240V-1.5KW-40VDC-NW-R1 is well suited as it would run at under 75% capacity to produce the necessary 10 amps. Running these units at 100% of their capacity can create excess heat and lead to shortened converter life.\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":38308194615477,"sku":"PL3-MT-PPS-120.240V-1.5KW-40VDC-NW-R1","price":13778.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/products\/PL3-MT-PPS-120.240V-1.5KW-40VDC-NW-R1.jpg?v=1629343844","url":"https:\/\/getcahits.com\/es\/products\/pl3-mt-pps-120-240v-1-5kw-40vdc-nw-r1","provider":"PuriLite","version":"1.0","type":"link"}